- 55 -
Position the main switch, connected to the supply
cable, in „0“ (zero) position. Check if the cable
section is suitable for the power consumed by the
device.
The power supply values are specified in the table
below:
400 V 3N 50/60 Hz
230 V 3 50/60 Hz
230 V 50/60 Hz
230 V 2 50/60 Hz
208 V 3 50/60 Hz
208 V 2 50/60 Hz
117261/
D6110
5 x 2.5 mm
2
4 x 2,5 mm
2
3 x 6 mm
2
//
4 x 12 AWG
//
117201/
D10110
5 x 4 mm
2
4 x 6 mm
2
//
//
4 x 8 AWG
//
The device must be connected to the potential levelling circuit of
efficiency conforming to the valid regulations.
The connection is the terminal fixed to the frame and marked with
the symbol in fig. 7.
5.6 Start-up and commissioning
•
Before the first start-up the device must be thoroughly inspected in order to confirm
the consistency of the device and its installation with the valid regulations, technical
data and recommendations for safety, included in this document.
Moreover take into consideration the following:
Temperature in the installation place must be higher than +4°C.
The device chamber must be empty.
Fig. 7
Fig. 6