5.4 Drain connection
Water flowing from the device drain may be hot
(90°C), therefore the drain hoses should be
resistant to such temperature.
The water drain is located in the bottom back
section of the device and is equipped with
connection pipe (Ø 40 mm).
Connect the pipe with the drain element (fig. 5,
pos. A).
The drain element is the water seal. However we
recommend to connect the drain pipe with open
funnel.
Check if the internal water seal is filled with water,
and if not, fill it through the drain in the device
chamber.
5.5 Electric connection
WARNING! Electric shock hazard!
The device can cause injuries due to improper installation!
Before installation and connecting the local power grid specification should be
compared with that of the device (see type label).
Connect the device only in case of compliance!
The electric installation must have appropriate earthing, conforming to the valid regulations.
The safety of the electric installation may be assured only when that installation fulfils the
requirements of the standards.
Before connecting the device make sure that the voltage and frequency values on the
rating plate are consistent with the existing electric installation. The allowable voltage
deviation is ±10%.
In order to connect the device directly to the power supply it is required to install the
interrupting switch between the device and the installation, suitable for the power. The
contacts of that switch must have the gap appropriate for the installation instructions,
assuring full disconnection in the overvoltage category III. The interrupting switch
should be installed in a place always accessible for the personnel.