- 33 -
RELIGHTING
•
Turn control knob to „0“.
•
Wait at least 5 minutes, to let gas dissipate, before attempting to re-light pilot.
•
Repeat steps mentioned in part „How to light the patio heater”.
EXTINGUISH
Hold knob depressed lightly & turn the knob clockwise to „0“.
Close the valve of the gas cylinder or the regulator after use.
NOTE!
Close the gas regulators after use and allow this appliance to cool
before moving the appliance.
GAS LEAK TESTING
CAUTION!
Never use a naked flame to check for leaks!
Never smoke while leak testing!
•
The gas connections on this appliance are leak tested at the factory prior to
shipment.
•
This appliance needs to be periodically checked for leaks and an immediate check
is required if the smell of gas is detected.
•
Make a soap solution using 1 part of liquid
dish-washing soap to 3 parts water. The
soap solution can be applied with a soap
bottle, brush, or rag to the leak tested
points shown in the figure to the right.
•
The valve of the gas cylinder should be in
the „OFF“ position at this point of the leak
test. Once the soapy solution is applied to
the gas connections, the valve of the gas
cylinder needs to be turned to the „ON“
position.
•
Soap bubbles will begin to form in the
soapy solution if a leak is present.
•
In case of a leak, turn off the gas supply.
Tighten any leaking fittings, then turn the
gas supply on and recheck.
Leak Test Point
①
②
③
④
Summary of Contents for 825131