- 35 -
o
The heater should be inspected before use and at least annually by a qualified service
person. More frequent cleaning may be required as necessary. It is imperative that
control compartment, burners and circulating air passageways of the appliance are
kept clean.
7. Possible Malfunctions
PROBLEM
CAUSE
SOLUTION
Pilot won’t light
Cylinder valve is closed
Open valve
Blockage in orifice or pilot
tube
Clean or replace orifice or pilot tube
Air in the gas line
Open gas line and bleed it (pressin
g control knob in) for not more than
1-2 minutes or until you smell gas
Low gas pressure
Gas cylinder low or empty
Igniter fails
Use match to light pilot, and
obtain new igniter and replace.
( See pictures page 36)
Pilot won’t stay lit
Dirt build up around pilot
Clean dirt from around pilot
Connection between gas
valve and pilot
assembly is loose
Tighten connection and perform
leak test
Burner won’t light
Gas pressure is low
Replace gas cylinder
Control knob is not in
„ON“ position
Turn control knob to „ON“ position
Burner flame
is low
Note: Do not
operate heater
below 50 °C (40°F)
Gas pressure is low
Replace gas cylinder
Outdoor temperature is
greater than 50 °C (40°F)
and tank is less than
25% full
Replace gas cylinder
Supply hose is interrupted
(e.g. bent hose)
Resolve interruption
and perform leak test on hose