background image

24/208 

 

it to the pressure gauge pipe. Open the appliance gas supply valve, check the pressure output, and 
close the valve. Remove the pressure  gauge pipe and screw the screws correctly into the pressure 
outlet. The pressure valve has to be within the minimum and maximum  values shown in the table 
TYPES OF GAS.

 

If the pressure measured is not within the limits shown in the table, find out the cause. After solving 
the problem, check the pressure again.

 

Checking the appliance power

 

Normally it is  sufficient  to  check that the  nozzles installed are the right  ones  and that the burners 
function properly. If desired, it is possible to check the power absorbed by using the “Volumetric 
Method”, measuring the volume of gas output supplied to the appliance in time units with the aid of 
a chronometer and a counter. The right comparison volume [

E

], measured in litres per hour (l/h) or 

in litres per minute (l/min), can be obtained using the formula shown below dividing the nominal and 
minimum outputs (power) shown in the table of burner features by the lowest heat capacity of the gas 
type pre-arranged for the appliance. This value can be found in the norm tables or can be provided by 
the local gas supply company.

 

 
The reading has to be done when the appliance is already in function. 

Checking pilot burner 

Check the flame of the pilot burner, which must be neither too short nor too high but must lap the 
thermocouple  and  have  a  sharp  form;  otherwise,  it  is  necessary  to  check  the  size  of  the  nozzle 
depending on the pilot version, as specified in the following paragraphs. 

 

Checking regulation of primary air

 

All the main burners are provided with primary air regulation. It is necessary to carry out the check 
observing  the  values  shown  in  the  air  regulation  column  of  the  burner  features  tables.  In  order  to 
regulate the primary air, proceed as specified in the following paragraphs.

 

ATTENTION! All the parts protected and sealed by manufacturer can not be regulated by the 
installer if not specifically indicated. 

MAINTENANCE 

ATTENTION! Before doing any kind of maintenance or repairs, make sure that the appliance 
is disconnected from the electric mains and that the gas cut-off valve is closed. 

The  following  maintenance  operations  have  to  be  carried  out  at  least  once  a  year  by  specialized 
personnel. It is advisable to have a maintenance contract. 

 

Check for correct functioning of all control and safety devices; 

 

Check for correct ignition of burners and proper functioning at minimum; 

 

Check the tightness of the gas pipes; 

 

Check the condition of the power cable; 

Power

Heat capacity

E =

Summary of Contents for 700 Series

Page 1: ...INSTALLATION USE AND MAINTENANCE Gas Bratt Pans Serie 700 2856031 2856811...

Page 2: ...e Table of gas types p 2 General Warnings p 19 Normes et Directives p 19 Installation and Gas Electric connection p 20 General Warnings for the Maintenance p 24 Gas Bratt Pans p 180 199 Cooking equipm...

Page 3: ...n mbar PMAX mbar G20 Methane 2H 20 17 25 G25 Methane 2ELL 20 17 25 G25 Methane 2E 25 20 30 G25 1 Methane 2HS 25 20 30 G25 3 Methane 2EK 25 20 30 G30 Butane 3B P 28 30 25 35 G30 Butane 3 28 30 20 35 G3...

Page 4: ...t be obstructed Children should be supervised to ensure they do not play with the appliance Before connecting the device make sure that the plate specifications correspond to the electrical and gas su...

Page 5: ...es for home professional use and industry SVGW Regulation of cantonal applications in Switzerland for ex fireproof regulations And the particular reference norms Declaration of compliance The manufact...

Page 6: ...mes evacuation Type A1 gas appliances The deep fat fryers are type A1 gas appliances and it is not necessary to connect directly to an evacuation pipe for combustion products The products of combustio...

Page 7: ...gs Gas Connection Before connecting the appliance it is necessary to check that the type of gas available corresponds to the type of gas the appliance has been set for In the event that they do not co...

Page 8: ...nly a single appliance to each switch In some cases after long periods of inactivity or in case of a new installation it is possible that the appliance switches off during the setting up The main reas...

Page 9: ...supply company The reading has to be done when the appliance is already in function Checking pilot burner Check the flame of the pilot burner which must be neither too short nor too high but must lap...

Page 10: ...B appliances following the prescriptions in force in the country of installation The gas tap should be lubricated but this operation is quite difficult and its results are not very reliable Therefore...

Page 11: ...atures p 181 Burners Features p 182 Dimensions p 185 Description of appliances p 199 Regulation using a different type of gas p 199 Substituting components p 201 Operating anomalies p 201 Instructions...

Page 12: ...Capacit cuve Tank capacity l 52 5 52 5 Gas Gaz B KW 12 5 12 5 Typ Type Typ A A1 A1 GPL LPG G30 D Kg h 0 986 0 986 Erdgas Methane G20 C m3 h 1 322 1 322 Luft Air m3 h 25 38 Gasanschluss Racc Gaz Gas f...

Page 13: ...mme Piloto N Aria Air Luft Aire x mm BRUCIATORE BR LEUR BURNER BRENNER QUEMADOR Liquid Gas PLG 12 50 AL125 x 2 16 2 1 5 G31 Tabella Tableau Table Tafel Tabla 77 CY MT HU NL CAT I3B P 29mbar Tipo gas T...

Page 14: ...EMADOR Natural Methan gas 12 50 AL190 x 2 27 2 0 5 G20 Liquid gas LPG 12 50 AL125 x 2 16 2 1 5 G30 G31 Tabella Tableau Table Tafel Tabla 81 CH SK DE AT CAT 2H3B P 50 mbar Tipo gas Type gaz Gas Type Ga...

Page 15: ...as 12 50 AL190 x 2 27 2 0 5 G20 Natural Methan gas 12 50 AL210 x 2 27 2 0 5 G25 Liquid gas LPG 12 50 AL105R x 2 16 2 1 5 G30 G31 Tabella Tableau Table Tafel Tabla 85 NL CAT II2EK3B P Tipo gas Type gaz...

Page 16: ...loto N Aria Air Luf t Aire x mm BRUCIATORE BR LEUR BURNER BRENNER QUEMADOR module Natural Methane Gas 12 50 AL190 x 2 27 2 0 5 G20 Liquid Gas LPG 12 50 AL125 x 2 16 2 1 5 G30 G31 Town Gas 11 80 AL380...

Page 17: ...nge to another gas type it is necessary to substitute the nozzles of the main burners and of the pilot burner following the instructions in the following paragraphs The nozzle type to be installed can...

Page 18: ...air of the burner After substituting the burner nozzle the primary air must be regulated Therefore loosen the screw 9 that fixes the bush 10 bring value X to the correct measurement tighten the screw...

Page 19: ...stall everything following the inverse sequence For better sealing it is advisable to screw the connections 9 to the valve by interposing a clamping screw Thermocouple In order to replace the safety v...

Page 20: ...power supply Check the condition of the heating element Check the thermostat No indicator light Check the power supply Check the light bulb Slow and or inadequate heating Check the setting of the ther...

Page 21: ...operation must always be carried out under surveillance If the lid is kept closed during cooking be careful when you lift it there is a risk to get burnt due to the steam produced inside the cooking v...

Page 22: ...for a long time it is advisable to turn off the gas tap Then disconnect the main electricity supply wipe all stainless steel surfaces with a cloth soaked in Vaseline oil in order to give it a protect...