background image

19/208 

 

GENERAL WARNINGS 

 

Read the instructions carefully before installation, use and maintenance of the appliance. 

 

The  installation  has  to  be  performed  by  qualified  personnel  following  the  manufacturer’s 
instructions given in the provided manual. 

 

The appliance is only suitable for the preparation and cooking of food in industrial kitchens such 
as those used in restaurants, hospitals, company canteens, cooking centres, butcher’s shops and 
food production firms. Any other type of use is not in accordance with the intended purpose and 
could place people and/or objects at risk. 

 

The appliance should only be used by trained personnel and for the use for which it was designed.  

 

Due  to  the  nature  of  the  appliance,  the  temperatures  required  for  cooking  may  cause  various 
areas of the panelling, as well as kitchenware, to become hot. This is not a construction defect, 
but a physical phenomenon caused by the chemical and physical properties of the materials used 
for the construction of the appliances. 

 

In the event of breakdown or malfunction, switch off the appliance and seek help exclusively from 
an authorized technical assistance centre. 

 

Only use genuine spare parts; otherwise no liability is assumed by the manufacturer. 

 

The appliance must not be washed with high pressure water sprays and the vents or inlets/outlets 
for air, fumes and heat must not be obstructed. 

 

Children should be supervised to ensure they do not play with the appliance. 

 

Before connecting the device make sure that the plate specifications correspond to the electrical 
and gas supply. 

 

When cooking, avoid placing pots and pans and/or crockery on the hotplate that could partially 
cover the stainless steel part of the hob, otherwise the worktop may overheat. 

 

When not in use, make sure the appliance is disconnected from the electric mains. 

 

At  the  end  of  the  installation  the  installer  must  explain  and  show  the  functioning  of  the 
appliance and shown to the user. After having ensured that everything is clear, the instruction 
booklet must be handed over. 

 

The user has to be informed that any building modification or restructuring that may in any way 
modify the air supply necessary for combustion makes it necessary to carry out another check of 
the  functionality  of  the  appliance.  In  particular,  every  variation  (additional  power)  in  the 
appliances in the room may modify the balance of the gas supply in the room. That means that 
appliances may be fed with gas at lower gas pressure and rate than those provided for and they 
may give worse performance.  

 

ATTENTION:  The  manufacturer  declines  any  liability  for  damage  caused  by  wrong 
installation,  tampering,  making  unauthorized  changes,  improper  use,  poor  maintenance, 
installation  of  non-original  spare  parts,  not  observing  local  norms,  incorrect  use  or  not 
observing the instructions in this booklet. 

Failure to observe even one of the above warnings will immediately void the warranty. 

 

 

Summary of Contents for 700 Series

Page 1: ...INSTALLATION USE AND MAINTENANCE Gas Bratt Pans Serie 700 2856031 2856811...

Page 2: ...e Table of gas types p 2 General Warnings p 19 Normes et Directives p 19 Installation and Gas Electric connection p 20 General Warnings for the Maintenance p 24 Gas Bratt Pans p 180 199 Cooking equipm...

Page 3: ...n mbar PMAX mbar G20 Methane 2H 20 17 25 G25 Methane 2ELL 20 17 25 G25 Methane 2E 25 20 30 G25 1 Methane 2HS 25 20 30 G25 3 Methane 2EK 25 20 30 G30 Butane 3B P 28 30 25 35 G30 Butane 3 28 30 20 35 G3...

Page 4: ...t be obstructed Children should be supervised to ensure they do not play with the appliance Before connecting the device make sure that the plate specifications correspond to the electrical and gas su...

Page 5: ...es for home professional use and industry SVGW Regulation of cantonal applications in Switzerland for ex fireproof regulations And the particular reference norms Declaration of compliance The manufact...

Page 6: ...mes evacuation Type A1 gas appliances The deep fat fryers are type A1 gas appliances and it is not necessary to connect directly to an evacuation pipe for combustion products The products of combustio...

Page 7: ...gs Gas Connection Before connecting the appliance it is necessary to check that the type of gas available corresponds to the type of gas the appliance has been set for In the event that they do not co...

Page 8: ...nly a single appliance to each switch In some cases after long periods of inactivity or in case of a new installation it is possible that the appliance switches off during the setting up The main reas...

Page 9: ...supply company The reading has to be done when the appliance is already in function Checking pilot burner Check the flame of the pilot burner which must be neither too short nor too high but must lap...

Page 10: ...B appliances following the prescriptions in force in the country of installation The gas tap should be lubricated but this operation is quite difficult and its results are not very reliable Therefore...

Page 11: ...atures p 181 Burners Features p 182 Dimensions p 185 Description of appliances p 199 Regulation using a different type of gas p 199 Substituting components p 201 Operating anomalies p 201 Instructions...

Page 12: ...Capacit cuve Tank capacity l 52 5 52 5 Gas Gaz B KW 12 5 12 5 Typ Type Typ A A1 A1 GPL LPG G30 D Kg h 0 986 0 986 Erdgas Methane G20 C m3 h 1 322 1 322 Luft Air m3 h 25 38 Gasanschluss Racc Gaz Gas f...

Page 13: ...mme Piloto N Aria Air Luft Aire x mm BRUCIATORE BR LEUR BURNER BRENNER QUEMADOR Liquid Gas PLG 12 50 AL125 x 2 16 2 1 5 G31 Tabella Tableau Table Tafel Tabla 77 CY MT HU NL CAT I3B P 29mbar Tipo gas T...

Page 14: ...EMADOR Natural Methan gas 12 50 AL190 x 2 27 2 0 5 G20 Liquid gas LPG 12 50 AL125 x 2 16 2 1 5 G30 G31 Tabella Tableau Table Tafel Tabla 81 CH SK DE AT CAT 2H3B P 50 mbar Tipo gas Type gaz Gas Type Ga...

Page 15: ...as 12 50 AL190 x 2 27 2 0 5 G20 Natural Methan gas 12 50 AL210 x 2 27 2 0 5 G25 Liquid gas LPG 12 50 AL105R x 2 16 2 1 5 G30 G31 Tabella Tableau Table Tafel Tabla 85 NL CAT II2EK3B P Tipo gas Type gaz...

Page 16: ...loto N Aria Air Luf t Aire x mm BRUCIATORE BR LEUR BURNER BRENNER QUEMADOR module Natural Methane Gas 12 50 AL190 x 2 27 2 0 5 G20 Liquid Gas LPG 12 50 AL125 x 2 16 2 1 5 G30 G31 Town Gas 11 80 AL380...

Page 17: ...nge to another gas type it is necessary to substitute the nozzles of the main burners and of the pilot burner following the instructions in the following paragraphs The nozzle type to be installed can...

Page 18: ...air of the burner After substituting the burner nozzle the primary air must be regulated Therefore loosen the screw 9 that fixes the bush 10 bring value X to the correct measurement tighten the screw...

Page 19: ...stall everything following the inverse sequence For better sealing it is advisable to screw the connections 9 to the valve by interposing a clamping screw Thermocouple In order to replace the safety v...

Page 20: ...power supply Check the condition of the heating element Check the thermostat No indicator light Check the power supply Check the light bulb Slow and or inadequate heating Check the setting of the ther...

Page 21: ...operation must always be carried out under surveillance If the lid is kept closed during cooking be careful when you lift it there is a risk to get burnt due to the steam produced inside the cooking v...

Page 22: ...for a long time it is advisable to turn off the gas tap Then disconnect the main electricity supply wipe all stainless steel surfaces with a cloth soaked in Vaseline oil in order to give it a protect...

Reviews: