background image

22/208 

 

Connection to  a chimney  with  forced pull, putting in  a pull device, letting out  the products  of 
combustion directly into the external environment. The energy supply to the appliance must be 
controlled by the system of forced evacuation and must be interrupted if its capacity falls below 
the values prescribed by the norms in force. Restarting the gas supply must only be done manually. 

 

Forced evacuation under hood

 

In this case, the fume evacuation device of the appliance must be brought to a height of 1.8 m 
from floor level, and the outlet section of the evacuation pipes for products of combustion must 
be  placed  inside  the  base  perimeter  of  the  hood.  The  energy  supply  to  the  appliance  must  be 
controlled by the system of forced evacuation and must be interrupted if its capacity falls below 
the values prescribed by the norms in force. Restarting the gas supply must only be done manually.  

 

INSTALLATION

 

Preliminary operations

 

Remove the appliance from the packaging, ensure that it is intact and, if in doubt, do not use it but 
contact  professionally  qualified  personnel.  The  packaging  materials  are  compliant  with 
environmental safety regulations. They can be stored without risk, or else should be disposed of in 
accordance  with  current  national  regulations,  particularly  those  regarding  the  nylon  bag  and  the 
polystyrene. 
After verifying that the appliance is in good conditions, the protective film may be removed. Clean 
the external parts of the appliance carefully with warm water and detergent, using a cloth to remove 
all remaining residues and then dry it with a soft cloth. If there are still traces of glue, these can be 
removed using a suitable solvent (e.g. acetone). Under no circumstances should abrasive substances 
be used. After the installation the appliance should be levelled by lowering or raising the adjustable 
legs.

 

Gas Connection

 

Before connecting the appliance, it is necessary to check that the type of gas available corresponds to 
the type of gas the appliance has been set for. In the event that they do not correspond, it is necessary 
to proceed as described in the paragraph 

Functioning with a gas type different from the type provided 

for

. The connection to the screwed pipe joints, which have a diameter of ½ inch and are situated on 

the appliance bottom, may be fixed or mobile by using a fitting quick-coupler. If flexible piping is 
used, it has to be made of stainless steel and meet the regulations in force. All the seals on the junction 
threads have to be made of materials certified for gas use. In order to ensure a quick interruption of 
the gas supply, before setting up each single appliance, it is necessary to install a cut-off cock; the 
device has to be placed in an easily accessible position so that it is possible to turn off the gas supply 
when the appliance is not used. After completing the connection, the tightness of the cut-off cock has 
to be checked by using a leak-finder spray. 

 

Electric connection

 

Before connecting the appliance, it is necessary to check that the voltage of the available power supply 
corresponds to the voltage the appliance has been set for. If they do not correspond, it is necessary to 
modify  the  connection  as  shown  in  the  electric  diagram,  if  voltage  change  is  provided  for.  The 
junction box is situated behind the control panel of the top and it is made accessible by unscrewing 
the screws that fix the panel, removing it and taking out the junction box.  
Furthermore, it is necessary to check that the earthing wire is efficient, that the earth conductor on 
the connecting side is longer than the other conductors, that the connecting cable has a 
wire  bunch  adequate  for  the  power  absorbed  by  the  appliance,  and  that  the  connecting 
cable is  at least type H07 RN-F. It is necessary to run the cable first through the cable 
gland.  

If the supply cord is damaged, it must be replaced by the manufacturer service 

Summary of Contents for 700 Series

Page 1: ...INSTALLATION USE AND MAINTENANCE Gas Bratt Pans Serie 700 2856031 2856811...

Page 2: ...e Table of gas types p 2 General Warnings p 19 Normes et Directives p 19 Installation and Gas Electric connection p 20 General Warnings for the Maintenance p 24 Gas Bratt Pans p 180 199 Cooking equipm...

Page 3: ...n mbar PMAX mbar G20 Methane 2H 20 17 25 G25 Methane 2ELL 20 17 25 G25 Methane 2E 25 20 30 G25 1 Methane 2HS 25 20 30 G25 3 Methane 2EK 25 20 30 G30 Butane 3B P 28 30 25 35 G30 Butane 3 28 30 20 35 G3...

Page 4: ...t be obstructed Children should be supervised to ensure they do not play with the appliance Before connecting the device make sure that the plate specifications correspond to the electrical and gas su...

Page 5: ...es for home professional use and industry SVGW Regulation of cantonal applications in Switzerland for ex fireproof regulations And the particular reference norms Declaration of compliance The manufact...

Page 6: ...mes evacuation Type A1 gas appliances The deep fat fryers are type A1 gas appliances and it is not necessary to connect directly to an evacuation pipe for combustion products The products of combustio...

Page 7: ...gs Gas Connection Before connecting the appliance it is necessary to check that the type of gas available corresponds to the type of gas the appliance has been set for In the event that they do not co...

Page 8: ...nly a single appliance to each switch In some cases after long periods of inactivity or in case of a new installation it is possible that the appliance switches off during the setting up The main reas...

Page 9: ...supply company The reading has to be done when the appliance is already in function Checking pilot burner Check the flame of the pilot burner which must be neither too short nor too high but must lap...

Page 10: ...B appliances following the prescriptions in force in the country of installation The gas tap should be lubricated but this operation is quite difficult and its results are not very reliable Therefore...

Page 11: ...atures p 181 Burners Features p 182 Dimensions p 185 Description of appliances p 199 Regulation using a different type of gas p 199 Substituting components p 201 Operating anomalies p 201 Instructions...

Page 12: ...Capacit cuve Tank capacity l 52 5 52 5 Gas Gaz B KW 12 5 12 5 Typ Type Typ A A1 A1 GPL LPG G30 D Kg h 0 986 0 986 Erdgas Methane G20 C m3 h 1 322 1 322 Luft Air m3 h 25 38 Gasanschluss Racc Gaz Gas f...

Page 13: ...mme Piloto N Aria Air Luft Aire x mm BRUCIATORE BR LEUR BURNER BRENNER QUEMADOR Liquid Gas PLG 12 50 AL125 x 2 16 2 1 5 G31 Tabella Tableau Table Tafel Tabla 77 CY MT HU NL CAT I3B P 29mbar Tipo gas T...

Page 14: ...EMADOR Natural Methan gas 12 50 AL190 x 2 27 2 0 5 G20 Liquid gas LPG 12 50 AL125 x 2 16 2 1 5 G30 G31 Tabella Tableau Table Tafel Tabla 81 CH SK DE AT CAT 2H3B P 50 mbar Tipo gas Type gaz Gas Type Ga...

Page 15: ...as 12 50 AL190 x 2 27 2 0 5 G20 Natural Methan gas 12 50 AL210 x 2 27 2 0 5 G25 Liquid gas LPG 12 50 AL105R x 2 16 2 1 5 G30 G31 Tabella Tableau Table Tafel Tabla 85 NL CAT II2EK3B P Tipo gas Type gaz...

Page 16: ...loto N Aria Air Luf t Aire x mm BRUCIATORE BR LEUR BURNER BRENNER QUEMADOR module Natural Methane Gas 12 50 AL190 x 2 27 2 0 5 G20 Liquid Gas LPG 12 50 AL125 x 2 16 2 1 5 G30 G31 Town Gas 11 80 AL380...

Page 17: ...nge to another gas type it is necessary to substitute the nozzles of the main burners and of the pilot burner following the instructions in the following paragraphs The nozzle type to be installed can...

Page 18: ...air of the burner After substituting the burner nozzle the primary air must be regulated Therefore loosen the screw 9 that fixes the bush 10 bring value X to the correct measurement tighten the screw...

Page 19: ...stall everything following the inverse sequence For better sealing it is advisable to screw the connections 9 to the valve by interposing a clamping screw Thermocouple In order to replace the safety v...

Page 20: ...power supply Check the condition of the heating element Check the thermostat No indicator light Check the power supply Check the light bulb Slow and or inadequate heating Check the setting of the ther...

Page 21: ...operation must always be carried out under surveillance If the lid is kept closed during cooking be careful when you lift it there is a risk to get burnt due to the steam produced inside the cooking v...

Page 22: ...for a long time it is advisable to turn off the gas tap Then disconnect the main electricity supply wipe all stainless steel surfaces with a cloth soaked in Vaseline oil in order to give it a protect...

Reviews: