Pag. 43/87
(Table 7) BURNER FEATURES (
DE, AT, CH – KAT. II
2ELL3B/P
,
II
2H3B/P
)
Gas type
Nominal
capacity
[kW]
Reduced
capacity [kW]
Diameter of main
injectors
[1/100 mm]
By-Pass
diameter
[1/100 mm]
Pilot injectors
[N°]
Air regulation
“x”
[mm]
FRYER BURNER ½ module
Liquid gas LPG
(G30-G31)
15.00
-
100
-
30
Open
Natural Methane gas
(G20)
14.60
-
170
-
51
Open
Natural Methane gas
(G25)
14.60
-
185
-
51
Open
FRY TOP BURNER 1 module
Liquid gas LPG
(G30-G31)
15.00 x 2
-
100 x 2
-
30 x 2
Open
Natural Methane gas
(G20)
14.60 x 2
-
170 x 2
-
51 x 2
Open
Natural Methane gas
(G25)
14.60 x 2
-
185 x 2
-
51 x 2
Open
WARNINGS
General
•
Read the instructions carefully before installation, use and maintenance of the appliance.
•
Installation must be carried out by qualified personnel following the manufacturer’s instructions
in the specific manual.
•
The appliance must only be used by trained personnel and only for the intended use.
•
In the event of breakdown or malfunctioning, switch off the appliance and call in after sales
assistance only from an authorized centre.
•
Use only original spare parts; otherwise no liability is accepted by the manufacturer.
•
The appliance must not be washed with high pressure water sprays, neither must the openings or
be blocked.
ATTENTION! The manufacturer declines any liability for damage caused by wrong
installation, tampering, making unauthorized changes, improper use, poor maintenance,
installation of non-original spare parts, not observing local norms, incorrect use or not
observing the instructions in this booklet
For the installer
•
The functioning of the appliance must be explained and shown to the user. After having ensured
that everything is clear, the instruction booklet must be handed over.
•
The user must be informed that any building modification or restructuring that may in any way
modify the air supply necessary for combustion, makes it necessary to carry out another check of
the functionality of the appliance.
Summary of Contents for 70 Series
Page 41: ......
Page 57: ...Pag 56 87 INSTALLATION BENUTZUNG UND WARTUNG ...