Pag. 41/87
(Table 2) BURNER FEATURES (IS - CAT.
I
3P
)
Gas type
Nominal
capacity
[kW]
Reduced
capacity [kW]
Diameter of main
injectors
[1/100 mm]
By-Pass
diameter
[1/100 mm]
Pilot injectors
[N°]
Air regulation
“x”
[mm]
FRYER BURNER ½ module (7 liter)
Liquid Gas PLG
(G31)
5,5 x 2
-
115
-
30 x 2
Open
FRYER BURNER ½ module
Liquid Gas PLG
(G31)
15.00
-
115
-
30
Open
FRYER BURNER 1 module
Liquid Gas PLG
(G31)
15.00x 2
-
115 x 2
-
30 x 2
Open
(Table 3) BURNER FEATURES (GB, IE, GR - CAT.
II
2H3+
)
Gas type
Nominal
capacity
[kW]
Reduced
capacity [kW]
Diameter of main
injectors
[1/100 mm]
By-Pass
diameter
[1/100 mm]
Pilot injectors
[N°]
Air regulation
“x”
[mm]
FRYER BURNER ½ module (7 liter)
Liquid gas LPG
(G30-G31)
5,5 x2
-
115 x 2
-
30 x 2
Open
Natural Methane gas
(G20)
5,5 x 2
-
170 x 2
-
51 x 2
Open
FRYER BURNER ½ module
Liquid gas LPG
(G30-G31)
15.00
-
115 x 3
-
30
Open
Natural Methane gas
(G20)
15.00
-
170 x 3
-
51
Open
FRYER BURNER 1 module
Liquid gas LPG
(G30-G31)
15.00 x 2
-
115 x 6
-
30 x 2
Open
Natural Methane gas
(G20)
14.60 x 2
-
170 x 6
-
51 x 2
Open
(Table 4) BURNER FEATURES (NL - CAT.
II
2L3B/P
)
Gas type
Nominal
capacity
[kW]
Reduced
capacity [kW]
Diameter of main
injectors
[1/100 mm]
By-Pass
diameter
[1/100 mm]
Pilot injectors
[N°]
Air regulation
“x”
[mm]
FRYER BURNER ½ module (7 liter)
Liquid gas LPG
(G30-G31)
5,5 x 2
-
115 x 2
-
30 x 2
Open
Natural Methane gas
(G25)
5,5 x 2
-
175 x 2
-
51 x 2
Open
FRYER BURNER ½ module
Liquid gas LPG
(G30-G31)
15.00
-
115 x 3
-
30
Open
Natural Methane gas
(G25)
15,00
-
175 x 3
-
51
Open
FRYER BURNER 1 module
Liquid gas LPG
(G30-G31)
15.00 x 2
-
115 x 6
-
30 x 2
Open
Natural Methane gas
(G25)
15.00 x 2
-
175 x 6
-
51 x 2
Open
Summary of Contents for 70 Series
Page 41: ......
Page 57: ...Pag 56 87 INSTALLATION BENUTZUNG UND WARTUNG ...