- 64 -
Cooking phases key
This key is used to select different phases forming a cooking programme.
By pressing the key F the operator can move to the next phase (the present phase
is indicated by the activated control lamp F1, F2, F3 or F4).
It is possible to change the parameters for each phase: time, temperature, steam
percentage, opening/closing of the steam extractor, fan speed and core
temperature.
Time + 1 key
This key is used to increase the value of the cooking time which appears on the
display; each press increases the value by 1 minute.
TEMPERATURE AREA
In this area of the control panel is located a rotary button used to set the cooking time
of the food. To increase or decrease the temperature which appears on the display,
turn the rotary button clockwise.
Fan speed key
This key is used to increase or decrease the fan speed. There are 6 options to set
the available fan speed.
The selected fan speed is indicated by the activated control lamp. To change the fan
speed from 1 to 2 etc. (max. to 6) and then get back to 1, press the key several times.
CORE TEMPERATURE SENSOR AREA
How to use the core temperature sensor correctly: Choose the thickest place in the food
to insert the core temperature sensor. Insert it from the top down until it hits the middle.
The inserted sensor measures the temperature of the food and stops the operation of
the device once the internal temperature set by using the rotary button has been
reached (the selected value of the core temperature sensor appears on the display).
This cooking method is used to set the cooking temperature (by turning the rotary button
of the temperature setting); however, it is not used to set the cooking time, because the
cooking process is stopped once the internal temperature of food controlled by the core
temperature sensor has been reached.
Note: It is necessary to ensure that the temperature set in the core temperature sensor
is lower than the temperature set for cooking, because otherwise the operation
continues without achieving the desired result, until the operator stops the combi
steamer manually.