- 74 -
6.2 Special maintenance
o
On a regular basis (at least one a year), have the device checked by a qualified
licensed technician. Please contact the customer service department for that matter.
o
Before performing any operation, disconnect the power supply, closing off the water
taps and wait until the combi steamer cools down.
o
Before moving the unit from its normal position, check if the wiring and piping are cut
off in the right way.
o
If the device has wheels make sure that electrical wires, tubes or other attachments
are not damaged in the process.
o
Avoid placing the unit near heat sources (such as fryers, etc.).
o
After the operation and position the device in its place of normal installation, and make
sure that all the electrical and water connections are made in accordance with the
standards before starting the unit.
Troubleshooting
In the event of a fault, disconnect the device from the power supply and turn off the
water supply. Before contacting customer service, check the nature of malfunction
described in the table below.
Fault
Reason
Solution
The device does not
start by pressing
the START/STOP
switch
•
The device door is not
closed
•
The microswitch does not
signal the closed device
door
•
Close the device door
•
Contact customer service
The device is
completely turned
off
•
No power supply
•
The power supply
connection has not been
established properly
•
The motor safety
thermostat has been
activated
•
Restore power supply
•
Check the power supply
connection
•
Contact customer service