5. Setup process of the X-series display
Image 5-3
3. The next stage is the installation of the remaining X-series tiles one by one and row by row.
Warning:
The maximum height of a hanging X-series display is 16 tiles tiles high.
Warning:
Make sure that all hoist engines work in a synchronized way. When the wall is tilted too much or tension on a hoist
is remarkably lower, stop the installation and level the wall
fi
rst.
Tip:
The full corner connection pieces have a M8 threaded bush to allow, if desired, the attachment of extra support points.
Tip:
After installing two rows of tiles, realize the data and power connection before lifting the rows further up. These rows are
now accessible from the work
fl
oor.
Tip:
If possible, add tiles one by one starting from the middle to the sides.
32
R5906024 X-SERIES 15/03/2016
Summary of Contents for X Series
Page 1: ...X series Installation manual second generation R5906024 01 15 03 2016 ...
Page 4: ......
Page 6: ...Table of contents 2 R5906024 X SERIES 15 03 2016 ...
Page 49: ...6 Basic Set up procedures Image 6 9 R5906024 X SERIES 15 03 2016 45 ...
Page 52: ...6 Basic Set up procedures 48 R5906024 X SERIES 15 03 2016 ...
Page 64: ...A Dimensions 60 R5906024 X SERIES 15 03 2016 ...
Page 72: ...B Specifications 68 R5906024 X SERIES 15 03 2016 ...
Page 76: ...C Order info 72 R5906024 X SERIES 15 03 2016 ...
Page 82: ...D Environmental information 78 R5906024 X SERIES 15 03 2016 ...
Page 84: ...Index X X series tile 16 80 R5906024 X SERIES 15 03 2016 ...