5. Mechanical Installation
464
464
160
490
4813
(screen to front of plate)
Image 5-6
Ceiling Mount fixation holes
Detailed drawings can be found in the Dimensions section.
How to mount the top parts of the ceiling mount ?
1. Place the gauge plate on the ceiling at the prescribed distance (4813 mm) to determine the mounting points
2. Determine and point out the position of the mounting points for M16 threaded rods (use above drawing)
3. Attach the 2 top parts of the 2 ceiling mounts to the ceiling using bolts that will guarantee a pull downward of at least 800kg
W
ARNING
:
Before mounting the assembly verify the rigidity and safety of the installed ceiling mount top part
!
R5976989 BARCO VR WORKROOM 22/09/2006