163
R5911443 /08
UDM
Image 11–17 Example of the laser bank group menu
6.
If you want notifications to be disabled for a specific group of laser banks, disable the
Enable notifications
for this group
slider.
11.6 Advanced settings – Tilt sensor calibration
CAUTION:
The calibration procedure resets the values of the tilt sensor to 0 in the current position
of the projector. For the optimal working of the tilt sensor it is important to make sure the projector is
perfectly level when performing this procedure. If not, the tilt sensor will not function as desired once
the calibration has been completed.
Required tools
Level
How to calibrate the tilt sensor?
1.
Place the projector on a flat surface and make sure it is positioned level in all directions. Use a level tool to
help ensure this.
2.
In the main menu, navigate to
Settings
→
Maintenance
→
Advanced
, while you are logged in.
Image 11–18 Maintenance menu, Advanced
3.
Enter the service code.
4.
In the
Service
menu, select
Tilt sensor calibration
.
Image 11–19 Advanced menu, Tilt sensor calibration
5.
Confirm your action.
Summary of Contents for UDM 4K15
Page 1: ...ENABLING BRIGHT OUTCOMES User manual UDM ...
Page 76: ...R5911443 08 UDM 76 GUI Image ...
Page 156: ...R5911443 08 UDM 156 GUI System Settings ...
Page 168: ...R5911443 08 UDM 168 GUI Status menu ...
Page 176: ...R5911443 08 UDM 176 Product maintenance ...
Page 192: ...R5911443 08 UDM 192 Video timing tables ...
Page 198: ...R5911443 08 UDM 198 DMX chart ...
Page 202: ...R5911443 08 UDM 202 WiFi GSM compliance information ...
Page 212: ...R5911443 08 UDM 212 List of tools ...
Page 218: ...R5911443 08 UDM 218 Index ...
Page 219: ......