4. Troubleshooting
4.3
No image on the TF-20 display
Troubleshooting check list
Situation
Possible reason
The display doesn’t light on.
1.
No power supply.
2.
The digitizer failed.
3.
The connection between the digitizer and the display is
incorrect.
The display has a bad image.
1.
The digitizer failed.
2.
The connection between the digitizer and the display is
incorrect.
The display brightness doesn’t match the ambient brightness.
1.
Incorrect connection of the external AEC cable.
2.
AEC failed.
24
R59770270 TF-20 21/05/2008