3. Diagnostics
3.1
TF-20 re-sync unit diagnostic
Status LED’s on the re-sync unit
The re-sync unit is provided with a yellow and a green status LED. These status LED’s are visible through the data output port of
the re-sync unit, see illustration below. Note that you have to unplug the data output of the re-sync unit to see the LED’s.
The controller and re-sync circuits are built on the same PCB board of the re-sync unit. The controller
fi
rmware
and controller software include the functionality of the re-sync unit. So, the TF-20 does not have a separate
fi
rmware
fi
le for the re-sync unit.
Y
G
Image 3-1
Location of status LED’s on the re-sync unit.
Y
Yellow colored status LED
G Green colored status LED
•
Reference
G
: Green LED indicating the status of the FPGA. Remains OFF until the FPGA is programmed correctly. Continuous
ON during normal operation.
•
Reference
Y
: Yellow LED indicating the status of the processor. The
fl
ash pattern of the yellow LED indicates
fi
ve different
statuses of the processor.
a) Flash pattern:
Normal operation of the processor. (0.5 second ON — 0.5 second OFF)
b) Flash pattern:
Processor is running in boot mode because of incorrect main program
fi
le. The software of the controller must be updated.
See user guide of the control software (e.g. Director toolset) for further instructions on how to update the software of the
controller. Note that when the processor is running in boot mode it is impossible to update the
fi
rmware of the controller.
(0.1 second ON — 0.1 second OFF)
c) Flash pattern:
Error in con
fi
guration of FPGA: Con
fi
guration done but con
fi
guration status of FPGA not correct. The
fi
rmware of the con-
troller must be updated. See user guide of the control software (e.g. Director toolset) for further instructions on how to
update the
fi
rmware of the controller. (2.5 seconds ON — 0.5 second OFF)
d) Flash pattern:
Error in con
fi
guration of FPGA: Con
fi
guration done but watchdog FPGA is not functioning. The
fi
rmware of the controller
must be updated. See user guide of the control software (e.g. Director toolset) for further instructions on how to update the
fi
rmware of the controller. (0.1 second ON — 0.1 second OFF — 0.1 second ON — 2 seconds OFF)
e) Flash pattern:
Error in con
fi
guration of FPGA: FPGA is con
fi
gured with backup
fi
le. Tile gives image, but OSD message “
fi
rm backup”
remains on screen until any other OSD command is given by the control software (e.g. Director toolset). The
fi
rmware of
the controller must be updated. See user guide of the control software for further instructions on how to update the
fi
rmware
of the controller. (2 seconds ON — 2 seconds OFF)
If any FPGA error, best is trying to upload new controller FPGA con
fi
g
fi
le (controller
fi
rmware). If problem
remains, replace re-sync unit.
18
R59770270 TF-20 21/05/2008
Summary of Contents for TF-20
Page 1: ...TF 20 Service Manual R59770270 00 21 05 2008...
Page 4: ......
Page 6: ...Table of contents 2 R59770270 TF 20 21 05 2008...
Page 13: ...2 General information 7 Image 2 5 7 Dust filter R59770270 TF 20 21 05 2008 9...
Page 24: ...3 Diagnostics 20 R59770270 TF 20 21 05 2008...
Page 47: ...6 Tile disassembling Image 6 18 R59770270 TF 20 21 05 2008 43...
Page 53: ...6 Tile disassembling Image 6 30 R59770270 TF 20 21 05 2008 49...
Page 56: ...6 Tile disassembling 52 R59770270 TF 20 21 05 2008...
Page 59: ...7 Tile reassembling Image 7 3 R59770270 TF 20 21 05 2008 55...
Page 92: ...C Specifications 88 R59770270 TF 20 21 05 2008...