BARCO 8
Daylight Display Systems
The exclamation point within a triangle is intended to tell the
user that important operating and/or servicing instructions are
included in the technical documentation for this equipment.
The lightning flash with an arrowhead within a triangle is
intended to tell the user that parts inside this product may
cause a risk of electrical shock to persons.
Risk of electric shock
Maximum ambient temperature
The maximum recommended ambient temperature for the LED wall is 50 ° C, the minimum temperature is -20 ° C.
High leakage current
The combination of multiple tiles in an installation results in increased levels of leakage current.
In order to avoid risk of electric shock due to high leakage current, proper grounding of the installation is required.
Risk of personnel injury
Secure all tiles in the rack. As a supplementary safeguard, and in order to protect against the risk of personnel injury,
each tile should be attached to the rack by a safety cable.
Flammable materials
Keep flammable materials away from the installation (such as curtains). A lot of energy is transferred into heat. The
installation should be such that the amount of air flow required for safe operation of the equipment is not compromised.
Proper ventilation must be provided.
Risk of electric shock/ Risk of fire
Power cables and connectors have been designed with special properties for outdoor use, and resistance against ingress of
water. Use only the factory recommended power cables and connectors.
Using other cables and connectors may result in risk of electric shock and risk of fire.
To protect against risk of fire by overloading of power cables,
MAXIMUM 6 TILES
in one column may be connected in
parallel. Each source cable supplying a column of
MAXIMUM 6 TILES
should be protected by a circuit breaker or fuses
rated 16 A / 250 V.
Disconnect device
When the appliance inlets of the individual tiles are not accessible, the socket outlets supplying the rack shall be installed
near the equipment and be easily accessible, or a readily accessible general disconnect device shall be incorporated in the
fixed wiring.
This equipment MUST be earthed
In order to protect against risk of electric shock, the installation should be properly grounded. Defeating the purpose of the
grounding type plug will expose you to the risk of electric shock.
Power system
It is recommended to use a TN-S power distribution system (a power distribution system with a separate neutral and
grounding conductor) in order to avoid large ground currents loops due to voltage differences in the neutral conductor. The
total electrical installation should be protected by an appropriate rated disconnect switch, circuit breakers and Ground Fault
Current Interrupters. The installation shall be done according to the local electrical installation codes. In Europe special
attention should be given to EN 60364, the standard for electrical installation of buildings. In Germany VDE 0100 should be
adhered to.
Mains cords
The power cords delivered with this system have special properties for safety. They are not user serviceable. If the power
cords are damaged, replace only with new ones. Never try to repair a power cord.
Safety Notice
IMPORTANT
WARNINGS