7. Important information
This Coronis 5MP complies with appropriate medical EMC standards on emissions to, and interference
from surrounding equipment. Operation is subject to the following two conditions: (1) this device may not
cause harmful interference, and (2) this device must accept any interference received, including interfer-
ence that may cause undesired operation.
Interference can be determined by turning the equipment off and on.
If this equipment does cause harmful interference to, or suffer from harmful interference of, surrounding
equipment, the user is encouraged to try to correct the interference by one or more of the following mea-
sures:
•
Reorient or relocate the receiving antenna or equipment.
•
Increase the separation between the equipment and receiver.
•
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
•
Consult the dealer or an experienced technician for help.
Electromagnetic immunity
The Coronis 5MP is intended for use in the electromagnetic environment speci
fi
ed below. The customer
or the user of the Coronis 5MP should assure that it is used in such an environment.
Immunity test
IEC 60601
Test levels
Compliance level
Electromagnetic
environment –
guidance
Electrostatic discharge
(ESD)
IEC 61000-4-2
± 6kV contact
± 8kV air
± 6kV contact
± 8kV air
Floors should be wood,
concrete or ceramic tile.
If
fl
oors are covered with
synthetic material, the
relative humidity should
be at least 30%
Electrical fast
transient/burst
IEC 61000-4-4
± 2kV for power supply
lines
± 1kV for input/ output
lines
± 2kV for power supply
lines
± 1kV for input/ output
lines
Mains power quality
should be that of a typical
commercial or hospital
environment
Surge
IEC61000-4-5
± 1 kV line(s) to line(s)
± 2 kV line(s) to earth
± 1 kV line(s) to line(s)
± 2 kV line(s) to earth
Mains power quality
should be that of a typical
commercial or hospital
environment
Voltage dips, short
interruptions and voltage
variations on power
supply input lines
IEC 61000-4-11
< 5% U
T
1
(> 95% dip in
U
T
) for 0.5 cycle
40% U
T
(60% dip in U
T
)
for 5 cycles
70% U
T
(30% dip in U
T
)
for 25 cycles
< 5% U
T
(>95% dip in
U
T
) for 5s
< 5% U
T
(> 95% dip in
U
T
) for 0.5 cycle
40% U
T
(60% dip in U
T
)
for 5 cycles
70% U
T
(30% dip in U
T
)
for 25 cycles
< 5% U
T
(>95% dip in
U
T
) for 5s
Mains power quality
should by that of a
typical commercial or
hospital environment. If
the user of the Coronis
5MP requires continued
operation during power
mains interruptions, it is
recommended that the
Coronis 5MP be powered
from an uninterruptible
power supply or a battery.
Power frequency (50/60
Hz) magnetic
fi
eld
IEC 61000-4-8
3 A/m
Not applicable
2
Power frequency
magnetic
fi
elds should
be at levels characteristic
of a typical location in
a typical commercial or
hospital environment.
Conducted RF
IEC 61000-4-6
3 Vrms
150 kHz to 80 MHz
3 V
Portable and mobile
RF communications
1. is the a.c. mains voltage prior to application of the test level.
2. Coronis 5MP doesn’t contain susceptible components to magnetic fields
40
B4100592 CORONIS 5MP 05/08/2014
Summary of Contents for MDCG-5121
Page 1: ...Coronis 5MP User Guide MDCG 5121 B4100592 03 05 08 2014...
Page 4: ...1 Welcome 2 B4100592 CORONIS 5MP 05 08 2014...
Page 8: ...2 Parts controls and connectors 6 B4100592 CORONIS 5MP 05 08 2014...
Page 22: ...4 Daily operation 20 B4100592 CORONIS 5MP 05 08 2014...
Page 34: ...5 Advanced operation 32 B4100592 CORONIS 5MP 05 08 2014...
Page 36: ...6 Cleaning your display 34 B4100592 CORONIS 5MP 05 08 2014...