16
MatrixPRO-
II
RJ-45 LAN Interface Cabling
This port is used to access the MatrixPRO-II via TCP-IP from
a host computer or network.
Cable type:
RJ-45 Crossover for direct computer to MatrixPRO-II control
RJ-45 Straight through for Network to MatrixPRO-II control
Recommended Maximum Length: 329 feet
Crossover Cable
Standard Patch Cable
RS-232 Remote Host Port Cabling (DB9)
The MatrixPRO-II has a standard RS-232
(DB9F) communication port that connects the
host PC to the Rack Unit allowing control and
confi guration.
Cable Type: Straight through DB-9 Male (To
mate with Female on Rack Unit) to DB-9
Male (to mate with DB-9 Male on typical PC
COMM port).
Recommended Maximum Length: 50 ft
7
5
8
3
2
RX
TX
RTS
GND
CTS
DB9M
(DTE)
7
5
8
3
2
DB9F
CABLE
GND
RX
TX
PC
(typical)
DB9M
RTS
CTS
7
5
8
3
2
7
5
8
3
2
Optional Flow Control Connections
If the device requires DSR, CD, or DTR,
implement loop -back handshake at the
device end of the cable as shown .
RN Remote
RS-232
Host Port
4
2
6
DTR
CD
DSR
4
2
6
NOTE: The default IP Address is: 192.168.0.244