14
MatrixPRO-
II
INSTALLATION
ENVIRONMENT
The Matrix rack unit should be mounted in a rack where an AC power outlet is nearby. It is a
direct AC plug in unit via the supplied EIA power cord. The front and back of the unit should be
positioned so that both the installer and operator can conveniently access the front and back for
wiring and adjustments.
Check each the manufacturer's recommendations on cable requirements and termination. Use stan-
dard approved wiring practices.
The integrity of all audio and video sources should be pretested BEFORE they are connected to
the Matrix rack. This holds true for the display devices as well. Simply direct connect the various
sources and displays to pretest the cable runs and equipment. The tested equipment can then be con-
nected to the Matrix rack unit. All terminations should have "ID" cable markers to aid in cabling and
troubleshooting.
In installing the Matrix rack unit in a suitable manner, the following is required:
1.
TMRA – The maximum recommended ambient temperature (TMRA) for the Matrix is 40°C.
2.
Ambient Temperature Inside the Rack – The ambient temperature inside the rack should not
exceed 55°C.
3.
Air Flow – Installation of the Matrix inside the rack should not impede air fl ow.
4.
Mechanical Loading – Mounting of the Matrix inside the rack shall not result in a hazardous
condition due to uneven loading.
5.
Circuit Overloading – Refer to equipment nameplate ratings when addressing branch circuit
and/or overcurrent protection requirements.
6.
Reliable Earthing – Reliable earthing of the Matrix shall be maintained after rack mounting.
Note – Earthing via the rack could be required if supply connection is not made directly to branch
circuit (e.g. use of power strips).