6. Control Unit
menu in the
I/O Control settings
tab, which can be used to route incoming audio signals directly to the physical outputs of the
soundcard(s).
6.2.7
Processing
About
The Processing service is the heart of the IOSONO CORE, where audio signals will be rendered to the loudspeaker setup utilized in
the preset according to the descriptive scene data. The source of audio signals (e.g. live-feed to the soundcard(s) input or playback
of an .icf
fi
le) is con
fi
gured using the corresponding settings in the General tab of the processing service.
While simultaneous rendering of audio from different devices is possible, there can only be one scene sender
active at a time for each object. Multiple scene data sources cannot control the same object.
For a detailed description of the rendering options please refer to the Step by Step Con
fi
guration chapter in "Initial System Con
gu-
ration", page 11that best resembles your type of application.
6.2.7.1
Sampleplayer Module
About
The SamplePlayer module is optional. If installed, it allows to play back up to 16 *.imf
fi
les in parallel using up to 16 sample-slots
simultaneously.
Playback can be controlled independently and simultaneously for all sample-slots.
The SamplePlayer is a module of the Processing service and can be activated and con
fi
gured from within the Processing Settings
page at General tab (see image 6-6).
Image 6-6
Overview Sampleplayer settings
The SamplePlayer functionality (loading, playback, stop, loop) can be controlled via the remote control protocol exclusively, but not in
the Control Unit (see "Commands", page 29 for available remote commands). The audio and scene data output of the SamplePlayer
is directly fed into the Renderer if available and does not appear at the input routing. Image image 6-7 shows extended settings
page for the SamplePlayer module.
R5906746 IOSONO CORE 08/05/2017
27
Summary of Contents for Iosono Core R9801500
Page 4: ......
Page 6: ...1 Introduction 2 R5906746 IOSONO CORE 08 05 2017 ...
Page 14: ...4 System Startup 10 R5906746 IOSONO CORE 08 05 2017 ...
Page 24: ...5 Initial System Configuration 20 R5906746 IOSONO CORE 08 05 2017 ...
Page 52: ...7 Step By Step Configuration 48 R5906746 IOSONO CORE 08 05 2017 ...
Page 60: ...8 Advanced System Tuning With The System Tuning Extension 56 R5906746 IOSONO CORE 08 05 2017 ...