background image

Online User Guide

Coronis Fusion

Summary of Contents for Coronis Fusion

Page 1: ...Online User Guide Coronis Fusion...

Page 2: ...This page intentionally left blank 2 This page intentionally left blank...

Page 3: ...tion and connection of a com plete system Online user guide html file installed on PC Gives a detailed description of how to operate the display using its local con trols and on screen display OSD Thi...

Page 4: ...ntents Previous Press this button to move to the previ ous help topic Next Press this button to move to the next help topic Related topics Press this button to display related top ics if available E m...

Page 5: ...Medical Displays only and not a complete BARCO CORONIS FUSION Display System you will need to refer to the user manual for the display controller you are using Languages supported The BarcoMed tabs su...

Page 6: ...select Personalization then click on Display Settings 2 Click on the Settings tab The Settings tab is not present in Vista 3 Select the rectangle that represents the BARCO CORONIS FUSION Display whos...

Page 7: ...e amount of time in hours that the backlight has been on The backlight will typically last a very long time but will only be able to hold the recommended calibrated luminance for a certain amount of t...

Page 8: ...for your BARCO CORONIS FUSION Display System click on the Advanced button in the Graphics Device Information section There are several pages accessible from the advanced configuration button They are...

Page 9: ...co Adapter Configuration page if two displays are enabled then the larger of the two current resolutions will be used If only one of the two displays is enabled the enabled display s current resolutio...

Page 10: ...ing application vendor provides detailed information on custom settings In the Custom Settings section the user can fine tune the following options Anisotropic filtering SMOOTHVISION Wait for Vertical...

Page 11: ...for Vertical Sync For OpenGL the default setting is Default Off For Direct3D the default setting is Application Preference Please refer to the on line help for more information on using advanced featu...

Page 12: ...ult To activate a particular profile select the application name from the list and click Apply This will add the information to the necessary Windows registry settings If prompted restart Windows If y...

Page 13: ...ers for the selected application To remove the selected configuration profile completely select the name of the application from the Configuration Profiles list box and click Delete Note You cannot de...

Page 14: ...same content on the same screen area may result in a form of image retention You can avoid or significantly reduce the occurrence of this phenomenon by using a screen saver You can activate a screen...

Page 15: ...olor matching throughout the economic lifetime of the system 5 Maximize Quality Assurance The MediCal QAWeb system offers online service for high grade Quality Assurance providing maximum diagnostic c...

Page 16: ...ecrease values in the OSD 2 Right Up touch key To move up or increase values in the OSD 3 Enter touch key To display the OSD on screen display In the OSD this button acts as Enter button to make selec...

Page 17: ...D panel Using the touch keys Stand by switching 1 While the OSD is not on the screen touch any touch key As a result the control panel illumination is switched on for a few seconds 2 While the contol...

Page 18: ...Next touch the Enter key to go into the submenu 3 When you select Exit the OSD exits the submenu and jumps to the previous higher level menu When you select Exit in the main menu the OSD is hidden Mak...

Page 19: ...and down through the menus 2 To go into a submenu rotate the control wheel to highlight the submenu Next click the control wheel to go into the submenu 3 When you click on Exit the OSD exits the subme...

Page 20: ...high This message appears in case the resolution of the selected video signal is too high to display Text mode Diagnostic mode These messages appear for a few seconds directly after switching to Text...

Page 21: ...itches to a safe operating mode with decreased backlight value The message will not disappear until the display is powered off On screen display OSD Luminance and color menu Luminance and color menu N...

Page 22: ...to edit these values Viewing mode Allows to select the viewing mode Diagnostic or Text In text mode the luminance is approximately half of the luminance in diagnostic mode This is intended for use wi...

Page 23: ...available only when the color target is defined in x y co ordi nates This function is not available when the Native White color target is selected y Allows to define the y co ordinate of the color tem...

Page 24: ...ption Display function Allows to select from a list of pre defined display functions If the DICOM DF is selected a number of additional settings is available ALC DICOM options Jumps to the ALC DICOM O...

Page 25: ...light determined for the selected reading room Correction value Shows the ambient light correction value that is taken into account in the calculation of the display function Cont DICOM ALC Allows to...

Page 26: ...nto account This function is available only when Continuous DICOM ALC is off Reading room Allows to select from a pre defined list of reading room types You must select a reading room that corresponds...

Page 27: ...type you are editing You can select another room to edit by using the Up or Down touch keys or rotating the control wheel Max ambient light This indicates the maximum ambient light that corresponds to...

Page 28: ...ting you to dim the light in the room and the value will be limited to the maximum ambient light value If you dim the light in the room you can execute the Measure ALC Value function again to enter th...

Page 29: ...ls key code is entered To enable the user controls again To enable the user controls again using the touch keys on page 32 or To enable the user controls again using the control wheel on page 32 Sound...

Page 30: ...to display only the signal connected to the Left video input Select Right to display only the signal connected to the Right video input Preferred Input Select the video resolution you wish the connec...

Page 31: ...as word processing Switching viewing modes by means of the keys While the OSD is not on the screen touch the Up and Down touch keys at the same time As a result the display switches to another viewin...

Page 32: ...ols keycode is entered see below To enable the user controls again using the touch keys 1 To enter the user controls keycode the OSD must not be visible 2 Touch any of the soft touch keys to switch on...

Page 33: ...the power LED on off 1 Open the OSD main menu 2 Open the Settings menu 3 Select Power LED 4 Select On or Off 5 Return to the Settings menu Note When the display is switched in stand by the power LED w...

Page 34: ...Measured ALC you must select a reading room that corresponds to the type of room the display is installed in E g if the display is installed in a room where CT scans are observed the CT MR NM reading...

Page 35: ...ction results in more visi ble grayscales in the images Dynamic Gamma 2 2 Dynamic Gamma 1 8 These are gamma functions that are shifted to take into account the non zero luminance of an LCD panel when...

Page 36: ...witched off the DICOM DF will be recalculated only when another DICOM Offset is selected To switch continuous DICOM ALC on off 1 Select the DICOM display function See To select a display function DF o...

Page 37: ...ous DICOM ALC is off Value Description Dark Room The DICOM DF will be recalculated tak ing an ambient light value of 0 lux into account This means that the measured ambient light does not influence th...

Page 38: ...AMMO Corresponds to light conditions in diag nostic reading rooms for computed radi ology digital radiology or mammography This setting has the lowest maximum ambient light DRR CT MR NM Corresponds to...

Page 39: ...e within certain limits determined by the selected reading room 6 To modify the Preset correction value for this reading room select Preset Corr Value and change the value You can change this value wi...

Page 40: ...selected reading room dim the light in the room so that the measured ambient light becomes lower that the maximum ambient light Then use Enter or click the control wheel again to execute the Measure A...

Page 41: ...Barco web sites 41 Barco web sites Visit Barco at http www barco com Visit Medical Imaging at http www barco com medical...

Page 42: ...Barco nv Medical Imaging President Kennedypark 35 B 8500 Kortrijk Belgium www barco com K5902016 01 October 2009...

Reviews: