263
ODPSUHDGPHVVDJHUXQWLPH
n
Description :
Read the run time when the message menu, indicating the
remaining lamp run time, first occurs. This message menu
is displayed for 1 minute and is repeated every 30 minutes
n
Command :
Command[0]
\x76
Command[1]
\x8b
n
Data :
No data bytes.
n
Return data :
The return data-transfer being the lamp message run time
in seconds consists of four data bytes. The first byte is the
most significant byte !
Formula :
Lamp message run time (seconds)
= Data[0]*2563 + Data[1]*2562 + Data[2]*256 + Data[3]
n
Projector type :
Not all projectors support this command.
n
Example :
Read the lamp message run time of a projector with
address \x01. Suppose the message appears at 970 hours.