261
ODPSUHDGPD[LPXPUXQWLPH
n
Description :
Read the maximum lamp run time in seconds. This is the
maximum guaranteed run time for the lamp.
n
Command :
Command[0]
\x76
Command[1]
\x89
n
Data :
No data bytes.
n
Return data :
The return data-transfer being the maximum lamp run time
in seconds consists of four data bytes. The first byte is the
most significant byte !
Formula :
Maximum lamp run time (seconds)
= Data[0]*2563 + Data[1]*2562 + Data[2]*256 + Data[3]
n
Projector type :
Not all projectors support this command.
n
Example :
Read the maximum lamp run time of a projector with
address \x01. Suppose the maximum is 1000 hours.
Transmit
Start
\xfe
Projector address
\x01
Command[0]
\x76
Command[1]
\x89
Checksum
\x00
Stop
\xff