ORJRUHDGVWDWXV
n
Description :
Read the status (on or off) of the logo.
n
Command :
Command[0]
\xf1
Command[1]
\x81
n
Data :
No data bytes.
n
Return data :
Data[0] = logo status.
Status
Data[0]
Off
\x00
On
\x01
n
Example :
Read the status of the logo of a projector with address
\x01. Suppose the status is on.
Transmit
Start
\xfe
Projector address
\x01
Command[0]
\xf1
Command[1]
\x81
Checksum
\x73
Stop
\xff