ODPSUHDGUXQWLPH
n
Description :
Read the lamp run time in hours.
n
Command :
Command[0]
\x64
n
Data :
No data bytes.
n
Return data :
The return data-transfer being the lamp run time in hours
consists of four data bytes. The first byte is the most
significant byte !
Formula :
Lamp run time (hours)
= Data[0]*2563 + Data[1]*2562 + Data[2]*256 + Data[3]
n
Example :
Read the lamp run time of a projector with address \x01.
Suppose the lamp run time is 100 hours.
Transmit
Start
\xfe
Projector address
\x01
Command[0]
\x64
Checksum
\x65
Stop
\xff