271
ODPSUHDGVWDWXV
n
Description :
Read the lamp status.
n
Command :
Command[0]
\x6c
n
Data :
No data bytes.
n
Return data :
Data[0] = lamp status.
Only bit0 (least significant bit) is significant.
bit#
bit = 0
bit = 1
bit0
nominal power
high power
n
Projector type :
BD8100, BG8100, BG8200, BG9200.
n
Example :
Read the lamp status of a projector with address \x01.
Suppose the lamp is configured in high power.
Transmit
Start
\xfe
Projector address
\x01
Command[0]
\x6c
Checksum
\x6d
Stop
\xff