A
Aligning with adjustable height frame
1. Set the frames to the required height.
Use a 10 mm socket spanner for the
4 screws.
Caution:
Make sure each frame is attached with all 4 screws.
2. Adjust the adjustable feet. Use a 13 mm fork spanner.
3. Make sure that the appliance is installed horizontally. Use a spirit level.
6.3.3
Connect the flue gas pipe
The appliance can be connected to steel pipes, double-walled insulated stainless steel
flues and flexible stainless steel flues with an outside diameter of 200 mm.
Caution:
• During operation of the appliance the outer side of the flue system
becomes hot. Refer to the installation instructions of the flue system for
safe installation. Follow these instructions with regard to safe distances to
combustible material.
If the appliance is installed on an unlined, masonry flue with a large diameter, consider
using a flue lining system to improve the performance of the appliance.
1. Connect the flue to the flue gas connection on the appliance. If necessary use a steel
flue adaptor.
2. If a flexible stainless steel flue is used, secure the flue connection with 2 clamps.
3. If the flue is connected to an existing (masonry) chimney, make sure that the gap
between the flue and the existing chimney is sealed, with ceramic wool or any other
applicable component (ask your flue system supplier for advice)
4. Make sure that all mechanical connections of the flue system are correctly used.
5. Make sure that all of the flue system is gas-tight,
6. Insulate any non-insulated pipes with ceramic insulation wool. Refer to
6.3.6
for the
material requirements.
6.3.4
Connect the external combustion air supply pipe
Warning:
Only when the optional convection ventilator / combustion air box or the
combustion air inlet box is used: make sure to remove one of the break out
plates in the combustion air inlet of the box . If you do not obey to do this,
there is a risk of a dangerous situation when firing the appliance.
Installation
Falcon 80/56
19
Summary of Contents for Falcon 80/56
Page 1: ...I Installation and maintenance manual Falcon 80 56 Serial number Production date...
Page 28: ...Annual maintenance 2 28 Falcon 80 56...
Page 31: ...9 9 Dimensions 9 1 Frameless appliance Dimensions Falcon 80 56 31...
Page 33: ...9 9 3 Appliance with 3 sided classic frame Dimensions Falcon 80 56 33...
Page 34: ...9 9 4 Appliance with 4 sided classic frame Dimensions 34 Falcon 80 56...
Page 37: ...Warranty Terms Falcon 80 56 3 37...
Page 38: ...Warranty Terms 3 38 Falcon 80 56...