1
insulation plate
2
Flammable mantel piece
3
Ceiling
4
Non-flammable spacer
5
Insulation plate back panel
6
Non-flammable false ceiling
7
Convection / ventilation air outlet
openings. Total minimum 440 cm
2
8
Insulation plate side panel
9
Insulation plate front panel
10
Convection / ventilation air inlet
openings. Total minimum 220 cm
2
Figure 16. Mantel piece clearances
A
Minimum 5 cm from top of glass
B
Flammable ceiling: minimum 60 cm from glass / Non flammable ceiling: minimum 50
cm from glass
C
Mantel piece depth maximum 30 cm
D
Flammable ceiling: minimum 10 cm / Non flammable ceiling: minimum 0 cm
E
Mantel piece depth: maximum 5 cm
F
Minimum 30 cm from top of glass
G
Minimum 5 cm
H
Minimum 10 cm to flammable floor (or put a non flammable floor stone (hearth plate)
with a depth of minimum 30 cm in front of the complete width of the glass)
Clearances
28
Gas Fire Front 90-60
Summary of Contents for 90-60 PF2
Page 60: ...3 Slide the strip downwards 4 Tighten the nut wings Maintenance 60 Gas Fire Front 90 60...
Page 78: ...9 9 BARBAS Airbox 160 with 4 insert models Dimensions 78 Gas Fire Front 90 60...
Page 79: ...9 10 BARBAS Airbox 320 with 4 insert models Dimensions Gas Fire Front 90 60 79...
Page 82: ...11 EU Declaration of Conformity EU Declaration of Conformity 82 Gas Fire Front 90 60...
Page 83: ...EU Declaration of Conformity Gas Fire Front 90 60 83...
Page 84: ...Your Barbas dealer 002 21 07 2022 352517 251 002...