(***) Both burners at minimum.
Heat changing surface: Entire front of the appliance.
Figure 42. Position of primary air inlets and gas injectors
Table 14: Dimensions of primary air inlet / gas injectors
No.
Natural gas
G20
Butane G30
Propane G31
Biopropane G31
Primary air inlet first main burner
A
Ø5.0 mm
1x Ø8x15 mm + 2x Ø3.5 mm
B
Ø4.0 mm
1x Ø8x15 mm + 2x Ø3.5 mm
C
Ø5.0 mm
1x Ø8x15 mm + 2x Ø3.5 mm
Primary air inlet second main
burner
D
Ø4.0 mm
1x Ø8x15 mm + 2x Ø3.5 mm
E
Ø4.0 mm
1x Ø8x15 mm + 2x Ø3.5 mm
F
Ø4.0 mm
1x Ø8x15 mm + 2x Ø3.5 mm
G
Ø4.0 mm
1x Ø8x15 mm + 2x Ø3.5 mm
First main burner gas injector
A
Ø1.50 mm
Ø0.75 mm
B
Ø1.30 mm
Ø0.65 mm
C
Ø1.50 mm
Ø0.75mm
Second main burner gas injector
D
Ø0.95 mm
Ø0.60 mm
E
Ø1.20 mm
Ø0.80 mm
F
Ø1.20 mm
Ø0.80 mm
G
Ø0.95 mm
Ø0.60 mm
Pilot light burner injector
Nr. 36 (SIT
0.977.091)
no 23 (SIT 0.977.150)
Technical specification
Gas Fire Front 90-60
67
Summary of Contents for 90-60 PF2
Page 60: ...3 Slide the strip downwards 4 Tighten the nut wings Maintenance 60 Gas Fire Front 90 60...
Page 78: ...9 9 BARBAS Airbox 160 with 4 insert models Dimensions 78 Gas Fire Front 90 60...
Page 79: ...9 10 BARBAS Airbox 320 with 4 insert models Dimensions Gas Fire Front 90 60 79...
Page 82: ...11 EU Declaration of Conformity EU Declaration of Conformity 82 Gas Fire Front 90 60...
Page 83: ...EU Declaration of Conformity Gas Fire Front 90 60 83...
Page 84: ...Your Barbas dealer 002 21 07 2022 352517 251 002...