1
Non-flammable hearth
2
Convection air inlet
3
Mantel piece
4
Steel studs
5
TV wall mount bracket
6
TV
7
Convection air outlet
8
Concentric flue
9
Non-flammable material
3
10
Air gap and spacers
11
Non-flammable insulation plate
12
Cable duct
Figure 20. TV installation - surface mounted
A
Minimum 25 cm between mantel piece and top of glass pane
B
Minimum thickness 2.5 cm
C
Minimum 5 cm clearance between bottom of TV and top of mantel piece
D
Minimum 2.5 cm horizontal clearance between front of TV and front of mantel piece
E
Minimum 2.5 cm
F
Minimum thickness 4 cm
G
Minimum 3 mm clearance between appliance and surrounding construction
3
Specifications according the installation instructions of the manufacturer of the concentric flue system
and local regulations.
Clearances
32
Gas Fire Front 90-60
Summary of Contents for 90-60 PF2
Page 60: ...3 Slide the strip downwards 4 Tighten the nut wings Maintenance 60 Gas Fire Front 90 60...
Page 78: ...9 9 BARBAS Airbox 160 with 4 insert models Dimensions 78 Gas Fire Front 90 60...
Page 79: ...9 10 BARBAS Airbox 320 with 4 insert models Dimensions Gas Fire Front 90 60 79...
Page 82: ...11 EU Declaration of Conformity EU Declaration of Conformity 82 Gas Fire Front 90 60...
Page 83: ...EU Declaration of Conformity Gas Fire Front 90 60 83...
Page 84: ...Your Barbas dealer 002 21 07 2022 352517 251 002...