Figure 19. Clearances concentric flue
4.10
Clearances for TV installation
Caution:
Prevent that the temperature around the TV and the TV cables
becomes higher than normal. The clearances given in this chapter prevent a
too high temperature when the TV installed above the appliance.
Important:
• Make sure to use a non-flammable insulation plate with a thickness of
minimum 4 cm for the front of the chimney enclosure. Refer to chapter
for specifications.
• Put the power supply and signal cables in a insulated cable duct behind
the front of the chimney enclosure. Make the insulated cable duct of
minimum 12 mm non-flammable insulation plates. Refer to chapter
for
specifications.
• To prevent too much heat radiation to the TV, install a mantel piece
between the TV and the top of the appliance.
Two methods to install the TV are possible:
• Surface mounted
• Flush mounted
Clearances
Gas Fire Front 90-60
31