Action
Result
Window SET
1. Present the target condition.
2. Send the SP1 Single Value Teach
command using IO-Link to configure the
target condition and return to Run mode.
Light SET
Dark SET
Opposed-Mode
Models:
Opaque Mode
Remote Input
Action
Result
Two-Point
Static TEACH
1. Present the output ON target condition.
2. Pulse the remote line once to enter TEACH
mode and configure the output ON light
level.
3. Present the output OFF target condition.
4. Pulse the remote line again to configure
the output OFF light level and return to
Run mode.
Accepted
1. The amber LED indicator is off and the
green indicator LED flashes three times.
2. The green and amber LED indicators flash
six times rapidly in unison (acceptance
flash).
3. The sensor returns to Run mode with valid
thresholds.
Invalid Teach Condition
1. The green and amber indicator LEDs flash
two times in unison.
2. The green and amber LED Indicators flash
six times rapidly in unison (acceptance
flash).
3. The sensor returns to Run Mode with
coerced thresholds.
Dynamic
TEACH
1. Pulse the remote line once to start the
Dynamic TEACH process.
2. Run the target application to configure the
ON and OFF conditions.
3. Pulse the remote line again to stop the
Dynamic TEACH process and return to
Run mode.
Window SET
1. Present the target condition.
2. Pulse the remote line once to configure the
target condition and return to Run mode.
Light SET
Dark SET
Opposed-Mode
Models:
Opaque Mode
WORLD-BEAM QS18 Expert with IO-Link
16
www.bannerengineering.com - Tel: + 1 888 373 6767