Method
Action
Result
Remote Input Wire—
Disable/Enable
From Run mode, pulse the remote
line four times.
Sensor toggles between enable/
disable settings and returns to
Run mode.
Green and amber LEDs flash four
times in unison followed by
acceptance flash.
Opposed-Mode Models:
Method
Action
Result
Push Button—Disable
Push Button: From Run mode, click
the button three times, then click
two times to disable the button.
Green and amber LEDs flash two
times in unison followed by
acceptance flash.
Remote: From Run mode, pulse the
remote three time, then pulse two
times to disable the button.
Push Button—Enable
Push Button: From Run mode, click
the button three times then click
one time to enable the button.
Green and amber LEDs flash
once in union followed by
acceptance flash.
Remote: From Run mode, pulse the
remote three time, then pulse one
time to enable the button.
Remote Input Wire—
Disable/Enable
From Run mode, pulse the remote
line four times.
Sensor toggles between enable/
disable settings and returns to
Run mode.
Green and amber LEDs flash four
times in unison followed by
acceptance flash.
WORLD-BEAM QS18 Expert with IO-Link
www.bannerengineering.com - Tel: + 1 888 373 6767