Install or Replace the Battery
When the FlexPower Supply Module is installed outdoors or in a high humidity environment, apply dielectric grease to the
battery terminals to prevent moisture and corrosion buildup.
To replace the lithium "D" cell battery in the FlexPower Supply Module, follow these steps.
1. Unplug the battery module from the SureCross device it powers.
2. Remove the four screws mounting the battery module face plate to the body and remove the face plate.
3. Remove the discharged battery by pressing the battery towards the negative terminal to compress the spring. Pry
up on the battery’s positive end to remove from the battery holder.
4. Replace with a new battery. Only use a 3.6 V lithium battery from Xeno, model number XL-205F.
5. Verify the battery’s positive and negative terminals align to the positive and negative terminals of the battery holder
mounted within the case. Caution: There is a risk of explosion if the battery is replaced incorrectly.
6. After replacing the battery, allow up to 60 seconds for the device to power up.
7. Properly dispose of your used battery according to local regulations by taking it to a hazardous waste collection
site, an e-waste disposal center, or any other facility qualified to accept lithium batteries.
As with all batteries, these are a fire, explosion, and severe burn hazard. Do not burn or
expose them to high temperatures. Do not recharge, crush, disassemble, or expose the
contents to water.
The battery may be replaced in explosive gas atmospheres.
Replacement battery model number: BWA-BATT-001. For pricing and availability, contact
Banner Engineering.
WARNING:
• Potential electrostatic charging hazard — only clean with a damp cloth.
• The replacement battery MUST be a Banner approved battery, model number BWA-BATT-001.
Use of a different battery will VOID the intrinsic safety rating of this device and may result in an
explosion!
• When replacing the battery, the negative end of the battery holder is the side with the spring
terminal. This side is marked with a minus (−) sign.
• Do not attempt to recharge the battery. These batteries are not rechargeable. Recharging may
cause serious injury to personnel or damage the equipment. Replace only with factory
recommended batteries.
Install or Replace the Battery (DX80 Models)
To install or replace a lithium "D" cell battery in any integrated housing model, follow these steps.
1. Remove the four screws mounting the face plate to the housing and remove the face plate.
2. Remove the discharged battery (if applicable) by pressing the battery toward the negative terminal to compress the
spring. Pry up on the battery’s positive end to remove from the battery holder.
3. Install the new battery. Only use a 3.6 V lithium battery from Xeno, model number XL-205F.
4. Verify the battery’s positive and negative terminals align to the positive and negative terminals of the battery holder
mounted within the case. The negative end is toward the spring.
Caution: There is a risk of explosion if the battery is replaced incorrectly.
5. After installing the battery, allow up to 60 seconds for the device to power up.
6. Properly dispose of used batteries according to local regulations by taking it to a hazardous waste collection site, an
e-waste disposal center, or other facility qualified to accept lithium batteries.