February 12, 2024
Q90R R-GAGE® Radar Sensor Instruction Manual
© Banner Engineering Corp. All rights reserved.
16
The remote input wire is disabled by default. Pulse the remote input wire 10 times or use the Banner Radar Configuration
software to enable the feature. After enabling the remote input feature, pulse the remote input according to the diagram and
the instructions provided in this manual. Remote teach can also be performed using the button on the Pro Converter Cable.
The length of the individual programming pulses is equal to the value T:
0.04 seconds ≤ T ≤ 0.8 seconds
.
Exit remote programming modes by setting the remote input Low for longer than 2 seconds or by waiting for 60 seconds.
FINAL DRAFT
Summary of Contents for R-GAGE Q90R
Page 22: ...22 F I N A L D R A F T...
Page 28: ...28 F I N A L D R A F T...