February 12, 2024
Q90R R-GAGE® Radar Sensor Instruction Manual
© Banner Engineering Corp. All rights reserved.
10
Primary Targets
Represents the signal strength and location of the strongest target inside the switch point.
Analog Window
The range the analog signal represents.
Available on analog models.
Varies by output model.
Discrete 1/2 Window
The range for the discrete output.
Varies by output model.
Switch Pt Lines
Displays the switch point distance.
Hysteresis Lines
Displays the hysteresis distance.
The Summary pane (blue shaded area) displays Distance, Signal Strength, and Output Status.
Distance
Displays the distance to the target.
Signal Strength
Displays the amount of excess gain of the signal received from the target. The excess gain is relative to the minimum
detection threshold (Signal Strength Threshold = 1).
Output Status
Displays whether the output is ON or OFF, or the analog output value (analog models only).
Set parameters for the sensor.
Click Read to read the connected sensor's current parameters. Click Write to write the parameters to the sensor. Yellow
highlight on a parameter's value indicates changes that have not yet been written to the sensor.
The following are the parameters on the General tab on the Sensor Settings pane.
Response Speed
Choose the response speed of the sensor (Slow, Medium, Fast).
Target Selection
Signal Strength Threshold
: Choose the threshold for the minimum amount of signal needed to actuate the output.
Target Mode:
Strongest Target
—Output responds to the target with the highest signal strength that is over the signal strength
threshold.
Nearest Target
—Output responds to the nearest target that is over the signal strength threshold.