no: do not reset to factory defaults
yes: reset to factory defaults
Two-Point Static Teach
Dynamic Teach
Background Suppression
Foreground Suppression
Top Menu
Sub Menu
off: no delays enabled
on: enable on and/or off delay (set value in Delay Timer menu)
1 Shot, fixed output pulse duration
Totalizer
sec range, set Delay Timer value (seconds have decimal)
display on
display on, inverted
display off (enters sleep mode after 60 seconds)
display off, inverted (enters sleep mode after 60 seconds)
end: exit setup
to
Teach Selection CH1
Output CH1
Window Size CH1 **
Response Speed CH1 & CH2
Output Timing Delays CH1
Delay Timer CH1 ***
Offset CH1 ****
Display Read CH1 & CH2
Exit Setup
Reset to Factory Defaults CH1 & CH2
Available when
set to
Available when
set to
ms
( default setting)
Light Operate
Dark Operate
Dual Mode
0.1 to 191 cm for 2000 mm models
Auto
Adaptive Tracking CH1 *
Menu not present when is set to
( and default to 0, defaults to 1 or 10
depending on response speed setting)
Set Value:
off: Adaptive Tracking off
High-Speed Adaptive Tracking on
on: Adaptive Tracking on
Channel 1
Window Size menu is available when Teach CH1 is set to FGS
Adaptive Tracking menu is available when Teach CH1 is set to Dual Mode
high excess gain mode
standard excess gain with increased noise immunity
Gain and Sensitivity CH1 & CH2
near: set zero displayed value to the housing face
far: set zero displayed value to maximum detection range
Select Zero Reference Location CH1 & CH2
on: move the zero point after each teach
off: zero point is either at the housing face or maximum
detection range
Shift Zero Reference after Teach CH1 & CH2
available when
set to
or
Offset menu is available when Teach CH1 is set to FGS or BGS
set Response Speed to 3 ms
2000 mm Model Response Speeds
set Response Speed to 5 ms
set Response Speed to 15 ms
set Response Speed to 50 ms
set Response Speed to 25 ms
-191 cm to 191 cm for 2000 mm models
Set value 0.1 to 200 cm
Sensor controls hysteresis dependent on distance value
Set value -0.1 to -200 cm
Hysteresis CH1
centimeter (with decimal point at < 100 cm)
inch (with decimal point at < 40 inches)
Distance Unit CH1 & CH2
IO-Link on Pin 4, PNP on Pin 2
Fixed PNP on Pins 2, 4
Output Type Polarity
Fixed NPN on Pins 2, 4
Figure 15. Sensor Menu Map—Channel 1
Q5X Laser Triangulation Sensor with Background Suppression
www.bannerengineering.com - Tel: +1.763.544.3164
9