3.6.3 One-Point Window (Foreground Suppression)
One-point window sets a window (two switch points) centered around the taught target distance. Loss of signal is treated
as a detection in One-Point Window mode. The size of the taught window is the vertical minimum object separation. See
Figure 24
on page 33.
Manually adjust the window size from Run mode using
and
.
Switch
Point
Value A
Switch
Point
Value -A
1
2
Press and
Hold > 2s
Press
again
3
Figure 22. One-Point Window (Foreground Suppression)
In order to reliably detect changes from the taught background, if multiple laser reflections are returning to the sensor, the
output status is treated as though the target is outside of the taught window. The display alternates between
and
the measured distance. Realign the laser to avoid light reflecting off of multiple targets if this extra level of verification is not
desired.
Note: The sensor must be set to
=
to use the following instructions. The FGS indicator is
amber to indicate One-Point Window (Foreground Suppression) mode.
Note: To program the sensor using remote input, remote input must be enabled (
=
).
1. Present the target.
Method
Action
Result
Push Button
Present the target. The sensor-to-target distance must be within the sensor's
range.
The target's measurement value displays.
Remote Input
2. Start the TEACH mode.
Method
Action
Result
Push Button
Press and hold TEACH for longer than 2 seconds.
Light Operate
and
flash alternately on
the display. The FGS indicator flashes.
Dark Operate
and
flash alternately on
the display. The FGS indicator flashes.
Remote Input
No action required.
N/A
3. Teach the sensor.
Method
Action
Result
Push Button
Press TEACH to teach the target.
The ± window size flashes rapidly and the
sensor returns to Run mode.
Remote Input
Single-pulse the remote input.
T
Q5X Laser Triangulation Sensor with Background Suppression
24