3.8 Display Menu (DISPLAY)
Use this menu to view or change
the:
• Display units
• Display orientation
• Sleep mode settings
MENU DISPLAY
or
or
Go Back to Parent Menu
Select Menu Item
Press to Save Setting
Press and Hold to Go Back
to Run Mode
DISPLAY Sleep
DISPLAY Units
Sleep 1min
Sleep Disabled
Units in
Units mm
DISPLAY View
View Invert
View Normal
Sleep 5min
Sleep 15min
Sleep 60min
DISPLAY Zero
Zero Near
Zero Far
DISPLAY Shift
Shift Off
Shift SetZero
Shift AutoSet
Figure 18. Display Menu Map
3.8.1 Units
The Units option sets the displayed units to millimeters (mm) or inches (").
Navigate: MENU > DISPLAY > Units
Remote Input: Not available
Default: mm
3.8.2 Zero and Shift
Use the Display Zero menu to select the zero reference location. The default is , 0 = the face of the sensor.
• Near—0 = the face of the sensor; the measurement increases further from the sensor
• Far—0 = maximum range; the measurement increases closer to the sensor
Use the Display Shift menu to select whether the sensor shifts the zero reference location based on the last TEACH
process. The default is Off (0).
• Off—0 = the face of the sensor or the maximum range, depending on the zero setting
• SetZero—Sets the current distance as its new zero reference location. This process is independent of teaching
analog or discrete set points.
• AutoSet—Shifts the zero reference location at the taught distance during any analog or discrete setting teach.
This figure illustrates three examples of how changes to the zero and shift settings affect what distance readout is shown on
the display when in 2-pt TEACH mode. Changes to the zero setting affect the direction in which the distance increases.
Turning the shift setting on sets the taught location as the reference point for any distance measurement.
L-GAGE
®
LTF Time of Flight Laser Distance Sensor with IO-Link
www.bannerengineering.com - Tel: + 1 888 373 6767
23