Storage Conditions
–30 °C to +65 °C (–22 °F to +149 °F)
Operating Conditions
–20 °C to +55 °C (–4 °F to +131°F)
90% at +55 °C maximum relative humidity (non-condensing)
Environmental Rating
IEC IP67; NEMA 6
Shock
MIL-STD-202G, Method 213B, Condition I (100G 6x along X, Y, and Z
axes, 18 shocks), with device operating
Vibration
MIL-STD-202G, Method 201A (Vibration: 10 Hz to 55 Hz, 0.06 inch (1.52
mm) double amplitude, 2 hours each along X, Y and Z axes), with
device operating
Application Note
For optimum performance, allow 15 minutes for the sensor to warm up
Certifications
Industrial
Control
Equipment
3TJJ
Required Overcurrent Protection
WARNING: Electrical connections must be
made by qualified personnel in accordance
with local and national electrical codes and
regulations.
Overcurrent protection is required to be provided by end product
application per the supplied table.
Overcurrent protection may be provided with external fusing or via
Current Limiting, Class 2 Power Supply.
Supply wiring leads < 24 AWG shall not be spliced.
For additional product support, go to
.
Supply Wiring (AWG)
Required Overcurrent Protection (Amps)
20
5.0
22
3.0
24
2.0
26
1.0
28
0.8
30
0.5
6.1 Repeatability Performance
LTF12 Models
6% Black Card
18% Gray Card
90% White Card
Distance in m (ft)
0
2
(6.6)
4
(13.12)
6
(19.7)
8
(26.2)
10
(32.8)
12
(39.4)
0
2 (0.08)
4 (0.16)
6 (0.24)
8 (0.31)
10 (0.39)
12 (0.47)
14 (0.55)
1σ R
ep
eat
ab
ili
ty
in mm
(inch)
Beyond Specified Range
Figure 24. Speed: Slow (256 ms)
6% Black Card
18% Gray Card
90% White Card
Distance in m (ft)
0
2
(6.6)
4
(13.12)
6
(19.7)
8
(26.2)
10
(32.8)
12
(39.4)
0
2 (0.08)
4 (0.16)
6 (0.24)
8 (0.31)
10 (0.39)
12 (0.47)
14 (0.55)
1σ R
ep
eat
ab
ili
ty
in mm
(inch)
Beyond Specified Range
Figure 25. Speed: Medium (32 ms)
0
2 (0.08)
4 (0.16)
6 (0.24)
8 (0.31)
10 (0.39)
12 (0.47)
14 (0.55)
6% Black Card
18% Gray Card
90% White Card
1σ R
ep
eat
ab
ili
ty
in mm
(inch)
Distance in m (ft)
0
2
(6.6)
4
(13.12)
6
(19.7)
8
(26.2)
10
(32.8)
12
(39.4)
Figure 26. Speed: Standard (8 ms)
0
2
(6.6)
4
(13.12)
6
(19.7)
8
(26.2)
10
(32.8)
12
(39.4)
Distance in m (ft)
6% Black Card
18% Gray Card
90% White Card
0
2 (0.08)
4 (0.16)
6 (0.24)
8 (0.31)
10 (0.39)
12 (0.47)
14 (0.55)
1σ R
ep
eat
ab
ili
ty
in mm
(inch)
Figure 27. Speed: Fast (1.5 ms)
L-GAGE
®
LTF Time of Flight Laser Distance Sensor with IO-Link
www.bannerengineering.com - Tel: + 1 888 373 6767
31