![Banner IVU BCR Series Instruction Manual Download Page 42](http://html.mh-extra.com/html/banner/ivu-bcr-series/ivu-bcr-series_instruction-manual_471801042.webp)
C-Mount Models
D
C
A
B
E
C
A
C-Mount Lens
B
Lens Enclosure
C
Retainer Ring (optional)
D Filter (optional)
E
Filter Retainer Ring Tool
NOTE: Filter Kits are available separately.
4.2 Setting Up a Barcode Application
This section describes how to set up the iVu BCR sensor.
1. Go to Main Menu > Inspection > Barcode Type to select one or more Barcode Types from the list.
NOTE: To ensure optimal performance, select only the barcode types for your application. For
example, if you use only one of the of the barcode types listed for All Linear, uncheck the box
next to All Linear, and select a radio button next to the desired linear barcode type. If you use
only DataMatrix, uncheck all the boxes except the one next to DataMatrix.
2. Go to Main Menu > Inspection > Barcode Count to select the number of barcodes (1 to 10) to be read at one
time.
After the sensor has been set up as described:
•
Each successfully read barcode is marked by a green bounding box. If annotations are on, the barcode data is also
displayed.
•
Any case where data does not compare is marked with a solid red bounding box. If the barcode is marked with a
dotted red bounding box, this indicates a checksum error or quiet zone violation.
iVu Barcode Reader (BCR)
42