Receiver
Display
LED Status
Possible Cause and Appropriate
Action
Alignment Top
Alignment
Bottom
Status Blocked
Status Clear
Yellow
flashing
Yellow OFF
Red
flashing
Green OFF
Optical
Fault
•
Open Reset/Test for at least 0.25 seconds and close.
•
Check for
optical
interference or noise.
If the
condition
continues,
contact Factory.
Alignment Top
Alignment
Bottom
Status Blocked
Status Clear
Yellow OFF
Yellow OFF
Red
flashing
Green OFF
Internal Fault
•
Open Reset/Test for at least 0.25 seconds and close.
•
Check the power supply for low or
erratic
voltage, or excessive electrical
noise.
•
Verify the sensor has a good earth ground.
If the
condition
continues,
contact Factory.
Alignment Top
Alignment
Bottom
Status Blocked
Status Clear
Yellow OFF
Yellow OFF
Red ON
Green ON
Reset/Test Input Fault
•
Reset/Test input open at power-up.
•
Switch the device OFF, verify the Reset/Test input is connected to +24 V
dc (e.g., the reset
button
or switch is closed) and reapply power.
Alignment Top
Alignment
Bottom
Status Blocked
Status Clear
Yellow OFF
Yellow OFF
Red ON
Green
flashing
Test Mode - Reset/Test input is open.
Alignment Top
Alignment
Bottom
Status Blocked
Status Clear
Yellow OFF
Yellow OFF
Red OFF
Green OFF
Power Supply Failure - Check power supply.
6.3 Electrical and
Optical
Noise
The EZ-SCREEN Type 2 is designed and manufactured to be highly resistant to electrical and
optical
noise and to operate reliably in
industrial
settings.
However, serious electrical and/or
optical
noise may cause a random In very extreme electrical noise cases, a Lockout
is possible. To minimize the
effects
of transitory noise, the EZ-SCREEN Type 2 responds to noise only if the noise is detected on
multiple
consecutive
scans.
If random nuisance Trips occur, check the following:
• Poor
connection
between the sensor and earth ground
•
Optical
interference from adjacent light screens or other photoelectrics
• Sensor input or output wires routed too close to noisy wiring
6.3.1 Sources of Electrical Noise
Checking for sources of electrical noise: It is very important that the light screen sensors have a good earth ground. Without this, the
System can act like an antenna and random Trips and Lockouts can occur.
All EZ-SCREEN Type 2 wiring is low voltage; running these wires alongside power wires, motor/servo wires, or other high-voltage wiring,
can inject noise into the EZ-SCREEN Type 2 System. It is good wiring
practice
(and may be required by code) to isolate EZ-SCREEN Type 2
wires from high-voltage wires.
The Banner model BT-1 Beam Tracker (see
on page 52 ) is a good tool for
detecting
electrical noise. It can be used to
detect electrical transient spikes and surges. Cover the lens of the BT-1 with electrical tape to block
optical
light from entering the
receiver lens. Press the RCV
button
on the BT-1 and
position
the Beam Tracker on the wires going to the EZ-SCREEN Type 2 or any other
nearby wires. The noise caused by switching of the
inductive
loads should be addressed by installing proper transient suppression
across the load.
6.3.2 Sources of
Optical
Noise
Checking for sources of
optical
noise: Turn
off
the
emitter,
completely block the
emitter,
or open the Test input, then use a Banner BT-1
on page 52 ) to check for light at the receiver. Press the RCV
button
on the BT-1 and move it across
the full length of the receiver’s sensing window. If the BT-1’s indicator lights, check for
emitted
light from other sources (other safety
light screens, screens or points, or standard photoelectric sensors).
EZ-SCREEN
®
Type 2 Light Screen
www.bannerengineering.com - Tel: 763.544.3164