background image

WARNING:

Do not use this device for personnel protection

Using this device for personnel protection could result in serious injury or death.

This device does not include the self-checking redundant circuitry necessary to allow its use in
personnel safety applications. A device failure or malfunction can cause either an energized (on)
or de-energized (off) output condition.

Important:

Never operate a 1 Watt radio without connecting an antenna

Operating 1 Watt radios without an antenna connected will damage the radio circuitry.

To avoid damaging the radio circuitry, never apply power to a Sure Cross

®

 Performance or Sure

Cross MultiHop (1 Watt) radio without an antenna connected.

Important:

Electrostatic discharge (ESD) sensitive device

ESD can damage the device. Damage from inappropriate handling is not covered by warranty.

Use proper handling procedures to prevent ESD damage. Proper handling procedures include
leaving devices in their anti-static packaging until ready for use; wearing anti-static wrist straps; and
assembling units on a grounded, static-dissipative surface.

7.4 Banner Engineering Corp. Limited Warranty

Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will

repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This

warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.

THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY

WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF

DEALING OR TRADE USAGE.

This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. 

IN NO EVENT SHALL BANNER ENGINEERING CORP. BE

LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL,

CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER

ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.

Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product

previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection

applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by

Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product

specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most

recent version of any documentation, refer to: 

www.bannerengineering.com

.

For patent information, see 

www.bannerengineering.com/patents

.

 

 

DXM Enclosure Kit (DEK) Series

 

www.bannerengineering.com - Tel: + 1 888 373 6767

21

Summary of Contents for DXM Series

Page 1: ...DXM Enclosure Kit DEK Series Instruction Manual Original Instructions 223953 Rev A 20 July 2021 Banner Engineering Corp All rights reserved 223953...

Page 2: ...Node to a DXM and Assign the Node Address 13 4 3 3 Conduct a Site Survey from the DXM 14 5 Activating Services 15 5 1 Banner Cellular Data Services 15 5 1 1 Activate Cell Services 15 5 1 2 Create an...

Page 3: ...ations typically isolated from traditional infrastructure A five watt solar panel delivers a nominal 12 V DC standard output built with a heavy duty anodized frame and rugged design for withstanding h...

Page 4: ...ord grips into locations 3 and 4 4 Install the smallest cable gland PG7 for the solar cable at location 2 2 2 Wire the Battery The battery and DXM ship from the factory pre mounted to the DIN rail 1 I...

Page 5: ...g cleat with the arc facing out Convex orientation b Leave the hardware a little loose so that the bracket can slide onto the panel frame between the mating surfaces c Move the cleat to the center of...

Page 6: ...p until it clicks closed 3 Wire the solar panel to the DXM Figure 5 Solar panel wiring to the DXM a Feed the cable from the solar panel to the DXM through the small cable gland b Connect the brown lea...

Page 7: ...eraging trending and thresholding Low complexity solutions SMS text message Notifications Email Notifications Push data on conditions Text Programming Language ScriptBasic Medium complexity solutions...

Page 8: ...1 1 1 1 1 1 LED2 TB1 C6 R82 TB4 P2 P4 SW1 C4 P5 SW2 P10 TB3 P7 TB2 TB9 Y1 P6 L2 TB5 TVS1 L1 R77 P9 P8 P1 LED1 P3 A B C D G H J K L 1 18 19 32 M L Pin Name Description 1 No Connection Not used 2 PW 12...

Page 9: ...registers 503 1A maximum at 30 V DC 24 N2 NMOS OUT 2 NMOS switch to ground controlled by I O Modbus registers 502 1A maximum at 30 V DC 25 N1 NMOS OUT 1 NMOS switch to ground controlled by I O Modbus...

Page 10: ...minute intervals Two DC latching outputs toggling every 5 minutes One temperature humidity probe powered from 16 V switched power reading every 5 minutes ScriptBasic program controlling temperature h...

Page 11: ...isters Local Registers in Use screen The bottom status bar displays the communications status application status and the DXM Configuration Software version In this short example we will configure the...

Page 12: ...e to display the parameters 3 Name your rule 4 Select the slave ID 5 Select how many registers to read and the beginning register 6 Define the register type how often to read the register and any othe...

Page 13: ...P switch 4 back OFF and cycle power again to return to normal operation of the XML and script Adjust the XML or script to slow down the RTU read or write rules Upload a blank XML bind all devices then...

Page 14: ...site survey on a DX80 network does not affect the throughput of the DX80 network The DX80 Gateway Node system can run a site survey analysis while the network is operational For a MulitHop network the...

Page 15: ...ellular data opening screen 3 Select the region the system is operating in If the system is within the contiguous United States select United States from the region drop down list If the system will b...

Page 16: ...ed to the cellular network 5 2 Banner Cloud Data Services BannerCDS 5 2 1 Activate Cloud Services Follow these instructions to activate your cloud services account 1 Go to the bannercds com website 2...

Page 17: ...nner Cloud Data Services website 3 Verify the Server Name IP is set to push bannercds com and the Page is set to push aspx for sending to the website 4 Set the Cloud Push Interval to a value appropria...

Page 18: ...esent your specific kit After the XML file is loaded into the webserver the webserver uses the register names and configurations defined in the configuration file 5 Click on the Site Name link to go t...

Page 19: ...d from the enclosure 6 Use the included screws to fasten the plate to the enclosure Do not over torque 7 Use the 2 13 16 to 3 3 4 pole clamps and the geometry of the plate tabs to fasten the enclosure...

Page 20: ...ensure no ground loops are created No surge suppressor can absorb all lightning strikes do not touch the Sure Cross device or any equipment connected to the Sure Cross device during a thunderstorm Ex...

Page 21: ...ANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND WHETHER ARISING UN...

Page 22: ...modify 17 save 13 upload 13 upload to website 18 configure cloud settings 17 create new site 16 M modify configuration file 17 multiple registers 11 registers 17 R registers multiple registers 11 S sa...

Reviews: