1
+
–
10–30 V dc
Gate
16–30 V dc
1.2 A Max.
2
3
4
5
6
7
8
9
10
13
14
F1
BROWN
BLUE
DRAIN
(BARE)
BLACK
WHITE
EMITTER and
RECEIVER CABLES
V-
V+
Power
12
11
NC
NC
NC
NC
15
30
through
16 Solid-state Ouputs
150 mA Max each
4.5 System Power Wiring
Wire the system power.
1. Connect a 16 to 30V dc source to controller terminals #1 (V+) and #2 (V–).
2. Connect a good earth ground to terminal #3.
A good earth ground is important for providing electrical and RF noise immunity to the MINI-ARRAY System. The dc power source must
supply 1.25 amps (worst case) when using the longest (6
ft)
sensors. See
on page 7 for more
information.
4.6 Gate Wiring
Connect a switched 10 to 30 V dc source as a
gating
input (if required) between controller terminal #11 (+) and #12 (-). Voltage is
typically switched by the open-collector output transistor of a dc sensing device.
4.7 Serial
Communication
Wiring
RS-485 (Models MAC-1, MACP-1, and MACN-1 only)— Connect RS-485 lines (if used) to terminals #13 (+) and #14 (-).
RS-232— Prepare an RS-232 cable using a DB-9 male connector with the
connections
shown. DO NOT use a “null modem” RS-232 cable.
RS-232 via a DB9
Connection
Pin
Description
5
1
9
6
2
Transmit (TX)
3
Receive (RX)
5
Ground (GND)
A-GAGE
®
MINI-ARRAY
®
Measuring Light Screen System
www.bannerengineering.com - Tel: 763.544.3164
15