![Banner A-GAGE MINI-ARRAY MAC-1 Instruction Manual Download Page 7](http://html1.mh-extra.com/html/banner/a-gage-mini-array-mac-1/a-gage-mini-array-mac-1_instruction-manual_3770108007.webp)
3
Specifications
3.1
Specifications
for the
Emitter/Receiver
Pairs
Range (9.5 mm Beam Spacing)
0.6 m to 6.1 m (2
ft
to 20
ft)
for sensors < 4
ft
0.6 m to 4.6 m (2
ft
to 15
ft)
for sensors > 4
ft
Maximum range is
specified
at the point where 3× excess gain remains.
Minimum Object
Sensitivity
(9.5 mm Beam Spacing)
19.1 mm (0.75 in)
Interlaced Mode: 12.7 mm (0.5 in)
Assumes sensing is in middle one-third of scanning range.
Supply Voltage and Current
(Emitter)
0.10 amps at 12 V dc
Maximum current is for a 6
ft
sensor.
Status Indicators
(Emitter)
Red LED lights for proper
operation
Construction
Aluminum housing with black anodized
finish;
acrylic lens cover
Range (19.1 mm Beam Spacing)
0.9 m to 17 m (3
ft
to 55
ft)
for sensors < 4
ft
0.9 m to 14 m (3
ft
to 45
ft)for
sensors > 4
ft
Maximum range is
specified
at the point where 3× excess gain remains.
Minimum Object
Sensitivity
(19.1 mm Beam Spacing)
38.1 mm (1.5 in)
Interlaced Mode: 25.4 mm (1 in)
Assumes sensing is in middle one-third of scanning range.
Supply Voltage and Current (Receiver)
9.5 mm beams: 0.75 amps at 12 V dc maximum
19.1 mm beams: 0.50 amps at 12 V dc maximum
Maximum current is for a 6
ft
sensor.
Status Indicators (Receiver)
Green: sensors aligned (> 3× excess gain)
Amber: marginal alignment (1×-3× excess gain)
Red: sensors misaligned or beam(s) blocked
Sensor Scan Time
55 microseconds per beam, plus 1 millisecond processing
time
per scan
Assumes straight scan,
continuous
scan, and TBB mode
Environmental
Rating
NEMA 4, 13 (IEC IP65)
Operating
Conditions
−
20 °C to +70 °C (
−
4 °F to +158 °F)
95% maximum
relative
humidity (non-condensing)
Connections
Emitter
and receiver connect to controller using two 5-conductor quick-
disconnect cables (one each for
emitter
and receiver), ordered separately.
Cables measure 8.1 mm (0.32 in ) dia., and are shielded and PVC-jacketed;
conductors are 20-gauge.
Use only Banner cables, which incorporate a "“twisted pair” for noise immunity
on RS-485 data
communication
lines.
Emitter
and receiver cables may not exceed 250
ft
each.
3.2 Dimensions for the
Emitters
and Receivers
With
Mounting
Bracket Flanges Out
With
Mounting
Bracket Flanges In
L1
L2
X
18.3 mm
[0.72”]
2.5 mm
[0.10”]
L3
10.2 mm
[0.4”]
38.1 mm square
[1.5”]
Housing Length
Distance Between Bracket Holes
Emitter/Receiver
Models
L1
L2
L3
BMEL6..A / BMRL6..A
201 mm (7.9 in)
233.9 mm (9.21 in)
177 mm (6.97 in)
BMEL12..A / BMRL12..A
356 mm (14 in)
389.7 mm (15.35 in)
332.8 mm (13.1 in)
BMEL18..A / BMRL18..A
505 mm (19.9 in)
538.7 mm (21.22 in)
481.8 mm (18.97 in)
BMEL24..A / BMRL24..A
659 mm (26 in)
693.2 mm (27.31 in)
636.3 mm (25.05 in)
A-GAGE
®
MINI-ARRAY
®
Measuring Light Screen System
www.bannerengineering.com - Tel: 763.544.3164