P/N 64118 rev. B
Installation and Mechanical Alignment
14
Banner Engineering Corp.
•
Minneapolis, U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
POWER
1
+
–
+
–
16-30V dc
1 A max
10-30V dc
GATE
SIGNAL
+30V dc max
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
F1
BROWN
BLUE
DRAIN (BARE)
BLACK
WHITE
DISCRETE
OUTPUT#1
150 mA
max
EMITTER and
RECEIVER CABLES
TX
TX
DISCRETE
OUTPUT#2 (ALARM)
+
–
10-30V dc
ALIGN
RS-485
+30V dc max
150 mA
max
25 mA
max
0-10V
ANALOG
OUTPUT #2
25 mA
max
0-10V
ANALOG
OUTPUT #1
Figure 3-3. MAHCVN-1 hookup
POWER
1
+
–
+
–
16-30V dc
1 A max
10-30V dc
GATE
SIGNAL
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
F1
BROWN
BLUE
DRAIN (BARE)
BLACK
WHITE
DISCRETE
OUTPUT#1
EMITTER and
RECEIVER CABLES
TX
TX
+
–
10-30V dc
ALIGN
RS-485
150 mA
max
25 mA
max
0-10V
ANALOG
OUTPUT #2
25 mA
max
0-10V
ANALOG
OUTPUT #1
DISCRETE
OUTPUT#2 (ALARM)
150 mA
max
Figure 3-4. MAHCVP-1 hookup
+30V dc max
POWER
1
+
–
+
–
16-30V dc
1 A max
10-30V dc
GATE
SIGNAL
+30V dc
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
F1
BROWN
BLUE
DRAIN (BARE)
BLACK
WHITE
EMITTER and
RECEIVER CABLES
DISCRETE
OUTPUT#2 (ALARM)
DISCRETE
OUTPUT#1
+
–
10-30V dc
ALIGN
Load
+16-30V
4-20 mA
ANALOG
OUTPUT#2
4-20 mA
ANALOG
OUTPUT#1
+16-30V
150 mA
max
150 mA
max
TX
TX
RS-485
Load
Figure 3-5. MAHCIN-1 hookup
+16 – 30V dc
+16 – 30V dc
POWER
1
+
–
+
–
16-30V dc
1 A max
10-30V dc
GATE
SIGNAL
4-20 mA
ANALOG
OUTPUT #1
4-20 mA
ANALOG
OUTPUT #2
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
F1
BROWN
BLUE
DRAIN (BARE)
BLACK
WHITE
EMITTER and
RECEIVER CABLES
DISCRETE
OUTPUT#2 (ALARM)
+
–
10-30V dc
ALIGN
Load
Load
150 mA
max
DISCRETE
OUTPUT#1
150 mA
max
TX
TX
RS-485
Figure 3-6. MAHCIP-1 hookup
3.3 Hookups
Refer to Figures 3-4, 3-5, 3-6, and 3-7 for the appropriate hookup information.