P/N 64118 rev. B
Specifications
8
Banner Engineering Corp.
•
Minneapolis, U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
Environmental Rating
Minimum Object Sensitivity
2.5 mm (0.1")
NEMA 4, 13 (IP65)
Sensor Scan Time
1.8 milliseconds to 58.4 milliseconds, depending on scanning method and sensor length; see Section
5.3.3 for detailed information
Power Requirements
12V dc ±2%, supplied by controller
Status Indicators
Emitter:
Red LED lights to indicate proper emitter operation
Receiver:
Green indicates sensors aligned
Yellow indicates marginal alignment of one or more beams
Red indicates sensors misaligned or one or more beam(s) blocked
Connections
Sensors connect to controller using two 5-conductor quick-disconnect cables (one each for emitter and
receiver), ordered separately. See page 5 for available lengths. Use only Banner cables, which incorporate
a “twisted pair” for noise immunity. Cables measure 8.1 mm (0.32") in diameter and are shielded and
PVC-jacketed. Conductors are 20 gauge (0.9 mm). Emitter and receiver cables may not exceed 75 m
(250') long, each.
Construction
Aluminum, with black anodized finish; acrylic lens cover
Operating Conditions
Temperature:
0° to +50°C (+32° to 122°F)
Maximum relative humidity:
95% at 50°C (non-condensing)
Emitter/Receiver Range
380 mm to 1.8 m (15" to 6')
2. Specifications
2.1 Emitter and Receiver Specifications
Certifications