![background image](http://html.mh-extra.com/html/bang-and-olufsen/ml-gateway/ml-gateway_installation-manual_471057046.webp)
Supported devices 46
Vantage
Connection to a Vantage system
Communication with a Vantage system is done through an
InFusion Dim Controller
. This device has both RS232 and Ethernet interfaces.
Connection to the RS232 interface can be done directly using a fully wired RS232 cable and it is fixed at no parity, 1 stop bit, 8 data bits. Make
sure to configure bit rate and flow control as needed. Connection settings for Ethernet are the IP address of the InFusion Dim Controller and its
telnet port.
Defining Vantage resources
To program the InFusion Dim Controller, the PC tool
Design Center
is needed. It lets you define all components of your Vantage system, where
each one has an address called
VID
(Vantage Identification Number).
On MLGW you can define as resources either a
button
on any control, or a
task
. To define a resource, you need to know the Button or Task vid,
wich must be entered in the ID field.
Vantage events and commands
An event corresponds to a Button press or release, or a Task activation or deactivation. Supported commands are
Button press and release
,
Button press
,
Button release
and
Task activation
.