![Bang & Olufsen ML Gateway Installation Manual Download Page 21](http://html.mh-extra.com/html/bang-and-olufsen/ml-gateway/ml-gateway_installation-manual_471057021.webp)
Programming 21
- Refer to the
System information
window and confirm that the software version is
2.7.166 or higher
! If the software version is older than version 2.7.166 the IHC controller must be updated to
the newest version. Contact the home automation installer to update the IHC controller.
- Choose Access control from the
LK IHC Administrator
menu
- Put a checkmark in the box for
Open for third party products
The IHC controller is now ready to commnuicate with ML Gateway. Disconnect the USB cable from the service PC and the ML Gateway. The next
step is to load the IHC definition file to the ML Gateway.
- Reconnect the Service PC to the network and access the web-based user interface
(by typing the IP address for ML Gateway in a web browser).
- Go to
Programming
->
Devices
->
IHC/LexControl
- Type an optional description and the IP address for the controller
- Click the
Add resources...
button in the Resources section.
- Click the
Browse
button to open the
Open
popup window.
- Choose the definition file from the project and click
Open
(contact the home automation
installer regarding how to export the definition file to the service PC).
- Click the
Load
button and the project file is loaded to the Resource section.